The application of chromatography-mass spectrometry: methods to metabonomics
… high chromatographic resolution assures the place of GC-MS as … Because GC-MS methods
for separating complex samples … a chromatographic peak alignment algorithm for GC-MS to …
for separating complex samples … a chromatographic peak alignment algorithm for GC-MS to …
[HTML][HTML] Determination of alkaloid compounds of Ricinus communis by using gas chromatography-mass spectroscopy (GC-MS)
…, IH Hameed, H Jasim, MA Kareem - Journal of Medicinal …, 2015 - academicjournals.org
… weight and exact mass are as shown in Table 1. The GC-MS chromatogram of the nine peaks
of the compounds detected are as shown in Figure 2-4. Chromatogram GC-MS analysis of …
of the compounds detected are as shown in Figure 2-4. Chromatogram GC-MS analysis of …
Application of gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry to the analysis of chemical warfare samples, found to …
RM Black, RJ Clarke, RW Read, MTJ Reid - Journal of Chromatography A, 1994 - Elsevier
… mass spectra, or at low concentrations by additional GC-MS-SIM analysis using chemical
iouisation, by higher resolution GC-MS-SIM, and by GC-tandem mass … GC-MS and GC-MS-MS …
iouisation, by higher resolution GC-MS-SIM, and by GC-tandem mass … GC-MS and GC-MS-MS …
Characterisation of beeswax in works of art by gas chromatography–mass spectrometry and pyrolysis–gas chromatography–mass spectrometry procedures
I Bonaduce, MP Colombini - Journal of Chromatography A, 2004 - Elsevier
… –gas chromatography–mass spectrometry (GC–MS) and a gas chromatography–mass …
The GC–MS analysis brought to light some essential differences in beeswax composition …
The GC–MS analysis brought to light some essential differences in beeswax composition …
… of 405 pesticide residues in grain by accelerated solvent extraction then gas chromatography-mass spectrometry or liquid chromatography-tandem mass …
GF Pang, YM Liu, CL Fan, JJ Zhang, YZ Cao… - Analytical and …, 2006 - Springer
… (ASE), solid-phase extraction (SPE), and GC-MS and LC-MS-MS. The method was based
on appraisal of the GC-MS and LC-MS-MS characteristics of 660 pesticides, their efficiency of …
on appraisal of the GC-MS and LC-MS-MS characteristics of 660 pesticides, their efficiency of …
Gas chromatography-mass spectrometry methods for structural analysis of fatty acids
WW Christie - Lipids, 1998 - Springer
… gas chromatography–mass spectrometry (GC–MS), GC … -phase high-performance liquid
chromatography (HPLC) are … lays particular emphasis on those GC–MS methods that the author …
chromatography (HPLC) are … lays particular emphasis on those GC–MS methods that the author …
Comparison of measured and recommended acceptance criteria for the analysis of seized drugs using Gas Chromatography–Mass Spectrometry (GC–MS)
JT Davidson, BJ Lum, G Nano, GP Jackson - Forensic Chemistry, 2018 - Elsevier
… indices and mass spectral ion abundances [43]. We hereby provide additional results of GC–MS
… to quantify the uncertainty of measurement in GC–MS measurements across a variety of …
… to quantify the uncertainty of measurement in GC–MS measurements across a variety of …
Gas chromatography–mass spectrometry of biofluids and extracts
AHM Emwas, ZA Al-Talla, Y Yang… - … : Methods and Protocols, 2015 - Springer
… , MS can be combined with other powerful analytical tools, such as gas chromatography (GC)
or liquid chromatography (LC), so MS … The main components of a GC–MS instrument are …
or liquid chromatography (LC), so MS … The main components of a GC–MS instrument are …
… fruits by application of gas chromatography–olfactometry (GC-O), odor activity value (OAV), gas chromatography-mass spectrometry (GC–MS) and flame photometric …
JC Zhu, LY Wang, ZB Xiao, YW Niu - Food Chemistry, 2018 - Elsevier
… the GC-FID-O, GC–MS and GC-FPD for desorption and analysis. The desorption time was
3 min; then the fiber was cleaned for 60 min in the 6890 gas chromatograph injector at 250 C. …
3 min; then the fiber was cleaned for 60 min in the 6890 gas chromatograph injector at 250 C. …
Enhancement of chemical derivatization of steroids by gas chromatography/mass spectrometry (GC/MS)
… GC/MS analysis The GC/MS analysis was performed using a Trace GC 2000 gas
chromatograph/quadrupole ion trap mass spectrometer with an AS3000 autosampler (Thermo …
chromatograph/quadrupole ion trap mass spectrometer with an AS3000 autosampler (Thermo …