Potentiometric determination of diazepam, bromazepam and clonazepam using solid contact ion-selective electrodes

AA Salem, BN Barsoum, EL Izake - Analytica chimica acta, 2003 - Elsevier
… Newly developed solid contact ion-selective electrodes (SC-ISE) have been proposed for
determining diazepam, bromazepam and clonazepam 1,4-benzodiazepines in pure forms and …

Highly reproducible solid contact ion selective electrodes: Emerging opportunities for potentiometry–A review

YH Cheong, L Ge, G Lisak - Analytica Chimica Acta, 2021 - Elsevier
potentiometric determination of a monovalent ion. As a result, to avoid huge errors in ion
determination, … In contrast, liquid-contact ISEs have reported much more reproducible potentials …

[HTML][HTML] Potentiometric solid-contact ion-selective electrode for determination of thiocyanate in human saliva

M Urbanowicz, K Sadowska, DG Pijanowska… - Sensors, 2020 - mdpi.com
Potentiometric sensors in the form of solid-contact ion-selective electrodes for the
determination of thiocyanate in human saliva were described. The comparison of metrological …

Solid-contact lead (II) ion-selective electrodes for potentiometric determination of lead (II) in presence of high concentrations of Na (I), Cu (II), Cd (II), Zn (II), Ca (II) and …

A Jasiński, M Guziński, G Lisak, J Bobacka… - Sensors and Actuators B …, 2015 - Elsevier
… The obtained sample solution was analyzed with AAS method and the solid contact ISEs …
potentiometric determination were used the same as in the synthetic sample determination. …

Potentiometric Solid‐Contact Multisensor System for Simultaneous Measurement of Several Ions

A Jasiński, M Urbanowicz, M Guziński… - …, 2015 - Wiley Online Library
… The characteristics of the electrodes for Na + , K + and Ca 2+ ions were determined using …
The potentiometric cells were used to determine the concentration of the ions in synthetic and …

Textile-based sampling for potentiometric determination of ions

G Lisak, T Arnebrant, T Ruzgas, J Bobacka - Analytica Chimica Acta, 2015 - Elsevier
… was in contact with potentiometric cell (detection side) and the side that it was in contact with
contact with the textile (t = 0 s) and after 60 s (arbitrarily chosen time of measurement in the …

Calibration-free potentiometric sensing with solid-contact ion-selective electrodes

CR Rousseau, P Bühlmann - TrAC Trends in Analytical Chemistry, 2021 - Elsevier
… at such high ion concentrations it can be difficult to determine … the performance of different
potentiometric sensing systems. … In such a case, the value of E 0 is determined as the average …

[HTML][HTML] A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva

M Urbanowicz, DG Pijanowska, A Jasiński… - Journal of Solid State …, 2019 - Springer
… on solid-contact ion-selective electrodes and miniaturized solid-contact reference electrode
… applied, which enabled simultaneous determination of selected ions in the small samples of …

Potentiometric ion sensors

J Bobacka, A Ivaska, A Lewenstam - Chemical reviews, 2008 - ACS Publications
… the concentrations of ions in the phases in contact are independent … ion-to-electron transducers
(solid-contact ISEs) has been dramatically improved. Solid-contact ISEs for determination

[HTML][HTML] Solid-contact ion-selective electrodes based on graphite paste for potentiometric nitrate and ammonium determinations

J Schwarz, K Trommer, M Mertig - American journal of analytical …, 2018 - scirp.org
contact material and as intermediate layer between the ion-selective membrane and the
graphite, polypyrrole has been used. It offers a definite transfer of ion … Solid-contact ion-selective …