Performance of a whole-body PET scanner using curve-plate NaI (Tl) detectors

LE Adam, JS Karp… - Journal of Nuclear …, 2001 - Soc Nuclear Med
… C-PET scanner. An image-quality phantom and patient data were used to evaluate image
quality under clinical scanning … PENN PET scanners, the C-PET, with its curved detectors and …

First results of a dedicated breast PET imager, BPET, using NaI (Tl) curve plate detectors

R Freifelder, C Cardi, I Grigoras… - 2001 IEEE Nuclear …, 2001 - ieeexplore.ieee.org
… Our design for a dedicated breast PET scanner uses two NaI(Tl) Curve Plate detectors in
contrast to other groups using small BGO or LSO crystals [3-6]. The “split-ring” design uses …

Design considerations for PET scanners

G Muehllehner, JS Karp, S Surti - The Quarterly Journal of …, 2002 - search.proquest.com
… In addition, we will emphasize the design consideration as PET scanners move from 2-D to
3… _] Cereb Blood of a whole-body PET scanner using curveplate NaI(Tl) detec— Flow Metal) …

A new high-resolution PET scanner dedicated to brain research

M Watanabe, K Shimizu, T Omura… - … on Nuclear Science, 2002 - ieeexplore.ieee.org
PET scanner (SHR-7700) having a 2.6 mm spatial resolution [6] and a brain PET scanner
(… mance of a whole-body PET scanner using curve-plate NaI(Tl) detectors,” J. Nucl. Med., vol. …

A high-sensitivity small-animal PET scanner: development and initial performance measurements

CM Kao, Q Xie, Y Dong, L Wan… - IEEE Transactions on …, 2009 - ieeexplore.ieee.org
plate geometry [14], [27]–[29]; and the use of detector plates naturally yields an extended …
curves at low radioactivity. It provides an estimate of the net sensitivity of a PET scanner with …

Advances in animal PET scanners

A Del Guerra, N Belcari - The Quarterly Journal of Nuclear …, 2002 - search.proquest.com
… Also in Italy, a high performance tomograph, YAP-(S) PET able to perform both PET and …
of this scanner are described. Tomographs with combined imaging techniques, such as PET/CT …

Performance evaluation of PETbox: a low cost bench top preclinical PET scanner

H Zhang, Q Bao, NT Vu, RW Silverman… - Molecular imaging and …, 2011 - Springer
… , a dedicated low cost preclinical PET scanner, referred to as … 3% peak absolute sensitivity
at the scanner center and ~2 mm … Time activity curves in major organs of a mouse during the 1 …

Test of a single module of the J-PET scanner based on plastic scintillators

P Moskal, S Niedźwiecki, T Bednarski… - Nuclear Instruments and …, 2014 - Elsevier
… A Time of Flight Positron Emission Tomography scanner based on plastic scintillators is
being developed at the Jagiellonian University by the J-PET collaboration. The main challenge …

[PDF][PDF] Physical principles and technology of clinical PET imaging

DW Townsend - Annals-Academy of Medicine Singapore, 2004 - annals.edu.sg
PET scan alone, the combined PET/CT scanner offers high-resolution anatomical imaging
irrespective of the specificity of the PET … Whole-body PET scanner using curved-plate NaI(Tl) …

Performance of a high sensitivity PET scanner based on LSO panel detectors

M Conti, B Bendriem, M Casey… - IEEE transactions on …, 2006 - ieeexplore.ieee.org
… and used to compute the NECR curve. A NECR measurement was … 2, the NECR curve is
shown in solid circles. Prompt … However, in typical clinical conditions the scanner operates …