Dedicated cone-beam breast CT using laterally-shifted detector geometry: Quantitative analysis of feasibility for clinical translation
S Vedantham, HW Tseng, S Konate… - Journal of X-ray …, 2020 - content.iospress.com
… High-resolution, low-noise detectors with minimal dead-… the dedicated cone-beam breast
CT (CBBCT). However, the smaller field-of-view necessitates laterally-shifted detector geometry …
CT (CBBCT). However, the smaller field-of-view necessitates laterally-shifted detector geometry …
Cone-beam micro computed tomography dedicated to the breast
A Sarno, G Mettivier, F Di Lillo, M Cesarelli… - Medical engineering & …, 2016 - Elsevier
… the detector, height of the detector with respect to the fixed focal spot height and rotation of
the detector around a horizontal axis for the detector … , and offset-detector geometries can be …
the detector around a horizontal axis for the detector … , and offset-detector geometries can be …
Investigation of the dose distribution for a cone beam CT system dedicated to breast imaging
N Lanconelli, G Mettivier, SL Meo, P Russo - Physica Medica, 2013 - Elsevier
… The system is comprised of a CMOS Flat Panel Detector with a 0.15-… In this study we do not
simulate the X-ray imaging detector, … We also notice that, thanks to the tomographic geometry, …
simulate the X-ray imaging detector, … We also notice that, thanks to the tomographic geometry, …
Radiation dosimetry of a clinical prototype dedicated cone‐beam breast CT system with offset detector
… A clinical prototype dedicated CBBCT with offset-detector geometry was designed 33, 34
and developed at our institution in collaboration with the industry (Koning Corp., West Henrietta…
and developed at our institution in collaboration with the industry (Koning Corp., West Henrietta…
Dedicated scanner for laboratory investigations on cone-beam CT/SPECT imaging of the breast
G Mettivier, P Russo, M Cesarelli, R Ospizio… - … , Detectors and …, 2011 - Elsevier
… breast with a dedicated scanner employing X-ray cone-beam irradiation geometry and a
flat panel digital detector, with the woman in the prone position and one breast at a time freely …
flat panel digital detector, with the woman in the prone position and one breast at a time freely …
An attenuation field network for dedicated cone beam breast CT with short scan and offset detector geometry
… For full-scan acquisition with offset-detector geometry, data redundancy from … breast CT
system, we propose to acquire short-scan data in conjunction with offset-detector geometry. To …
system, we propose to acquire short-scan data in conjunction with offset-detector geometry. To …
Cone‐beam breast computed tomography with a displaced flat panel detector array
G Mettivier, P Russo, N Lanconelli, SL Meo - Medical Physics, 2012 - Wiley Online Library
… This work describes the implementation of a dedicated acquisition technique for x-ray
computed tomography (CT) with cone-beam geometry, with specific application to breast CT. …
computed tomography (CT) with cone-beam geometry, with specific application to breast CT. …
Analysis of a novel offset cone-beam computed mammotomography system geometry for accomodating various breast sizes
RL McKinley, MP Tornai, C Brzymialkiewicz, P Madhav… - Physica Medica, 2006 - Elsevier
… X-ray detector in a compact geometry, we obtained … dedicated conebeam transmission
computed mammotomography (CmT) system configuration for attenuation correction of dedicated …
computed mammotomography (CmT) system configuration for attenuation correction of dedicated …
Cone beam breast CT with a flat panel detector-simulation, implementation and demonstration
CC Shaw, L Chen, MC Altunbas, S Tu… - … IEEE Engineering in …, 2006 - ieeexplore.ieee.org
… pendant geometry and a FP flat panel detector have been proposed and investigated by …
of using the cone-beam CT technique for dedicated breast imaging. The detection and …
of using the cone-beam CT technique for dedicated breast imaging. The detection and …
A comprehensive analysis of coefficients for pendant‐geometry cone‐beam breast computed tomography
JM Boone, N Shah, TR Nelson - Medical physics, 2004 - Wiley Online Library
… to breast CT was evaluated using Monte Carlo techniques over a range of parameters pertinent
to the cone-beam pendant geometry … mammography detection and prior to breast biopsy …
to the cone-beam pendant geometry … mammography detection and prior to breast biopsy …
相关搜索
- dedicated cone beam breast scatter correction
- dedicated cone beam breast feasibility study
- dedicated cone beam breast projection angle
- dedicated cone beam breast short scan
- dedicated cone beam breast clinical translation
- cone beam breast ct scanner
- cone beam breast computed tomography
- cone beam breast ct system
- dual resolution cone beam breast
- offset detector cone beam breast
- detector simulation cone beam breast
- experimental phantom study cone beam breast
- wavelet regularization cone beam breast
- radiochromic films cone beam breast
- scanning technique cone beam breast
- radiation dose cone beam breast