Open-ended coaxial dielectric probe effective penetration depth determination

PM Meaney, AP Gregory, J Seppälä… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
… While there is some influence to the property measurements from the second layer beyond
the prescribed depth developed in this analysis, the influence is minimal. When requiring …

Towards accurate microwave characterization of tissues: Sensing depth analysis of open-ended coaxial probes with ex vivo rat breast and skin tissues

C Aydinalp, S Joof, T Yilmaz - Diagnostics, 2021 - mdpi.com
coaxial probe sensing depth with samples with varying heterogeneity in an attempt to understand
the effect of dielectric property difference on sensing depth. … open-ended coaxial probe. …

Towards non-invasive diagnosis of skin cancer: Sensing depth investigation of open-ended coaxial probes

C Aydinalp, S Joof, T Yilmaz - Sensors, 2021 - mdpi.com
probe sensing depth. To this end, this work (1) investigates the sensing depth of the 2.2
mm-diameter open-ended coaxial probedepth characterization of open-ended coaxial probes. …

Characterization of open-ended coaxial probe sensing depth with respect to aperture size for dielectric property measurement of heterogeneous tissues

C Aydinalp, S Joof, I Dilman, I Akduman, T Yilmaz - Sensors, 2022 - mdpi.com
… Sensing depth analysis of open-ended coaxial probe for skin cancer detection. In
Proceedings of the 2019 23rd International Conference on Applied Electromagnetics and …

Open-ended coaxial probe technique for dielectric measurement of biological tissues: Challenges and common practices

A La Gioia, E Porter, I Merunka, A Shahzad… - Diagnostics, 2018 - mdpi.com
… with an open-ended coaxial probe. Given the high number of … each step of the coaxial
probe measurement procedure, … , followed by an in-depth analysis of the related confounders. …

Predicting the sensing radius of a coaxial probe based on the probe dimensions

A La Gioia, A Santorelli, M O'Halloran… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
… The thickness of the Teflon block was selected so that it was larger than the sensing depth
of the probe. The radius of the Teflon aperture was chosen by ensuring that the sensing …

Sensing volume of open-ended coaxial probes for dielectric characterization of breast tissue at microwave frequencies

DM Hagl, D Popovic, SC Hagness… - IEEE Transactions …, 2003 - ieeexplore.ieee.org
… Experimental measurements were conducted in [21] using a flanged Teflon-filled coaxial
probe to investigate the influence of the depth dimension of a low-loss solid sample (paper) on …

An analysis of open-ended coaxial probe sensitivity to heterogeneous media

CL Brace, S Etoz - Sensors, 2020 - mdpi.com
… However, heterogeneities in the probe sensing region … an analysis of the coaxial probe
sensing region to elucidate the effects of heterogeneities on measured permittivity. Coaxial probe

Sensing depth analysis of open-ended coaxial probe for skin cancer detection

C Aydinalp, S Joof, T Yilmaz - 2019 23rd International …, 2019 - ieeexplore.ieee.org
… Furthermore, the sensing depth of the 2.2mm aperture open-ended coaxial probe was
analyzed at five different frequencies. The results obtained show that the sensing depth of …

Open-ended coaxial dielectric probe model for biological tissue sensing depth analysis at 2 GHz

A Šarolić - 2019 European Microwave Conference in Central …, 2019 - ieeexplore.ieee.org
… from the probe open-end plane). The aim of this paper is to build a simulation model of
the open-ended coaxial probe in order to examine the observations on the sensing depth in …