Detection of atrial fibrillation in patients with embolic stroke of undetermined source by prolonged monitoring with implantable loop recorders
C Israel, A Kitsiou, M Kalyani… - Thrombosis and …, 2017 - thieme-connect.com
… In the present study, ILR-based monitoring for a period of 1 year detected AF in 23.6 % of
patients with an embolic stroke meeting the definition of ESUS. AF detection by the ILR could …
patients with an embolic stroke meeting the definition of ESUS. AF detection by the ILR could …
Detection and management of atrial fibrillation after cryptogenic stroke or embolic stroke of undetermined source
… Cryptogenic stroke (CS) and embolic stroke of unknown source (… fibrillation (AF) is commonly
found after CS or ESUS. Independent of the mechanism of the index CS or ESUS, detection …
found after CS or ESUS. Independent of the mechanism of the index CS or ESUS, detection …
Detecting atrial fibrillation in patients with an embolic stroke of undetermined source (from the DAF-ESUS registry)
JMR Campal, MAG Torres, PS Borque… - The American journal of …, 2020 - Elsevier
… We have set up the Detection of Atrial Fibrillation In ESUS … monitoring group) may detect a
comparatively large proportion … This software has an arrhythmia-detection algorithm; using this …
comparatively large proportion … This software has an arrhythmia-detection algorithm; using this …
Temporal relationship between subclinical atrial fibrillation and embolic events
M Brambatti, SJ Connolly, MR Gold, CA Morillo… - Circulation, 2014 - Am Heart Assoc
… Thirty percent of ASSERT patients with SCAF and ischemic stroke or systemic embolism
had SCAF detected only after their embolic event. This was despite >1 year of negative …
had SCAF detected only after their embolic event. This was despite >1 year of negative …
Monitored atrial fibrillation duration predicts arterial embolic events in patients suffering from bradycardia and atrial fibrillation implanted with antitachycardia …
… of arterial embolic events and to evaluate the clinical significance of AF as detected by …
increase by a factor of 2.7 in the risk of embolic events. Multivariate logistic analysis showed that …
increase by a factor of 2.7 in the risk of embolic events. Multivariate logistic analysis showed that …
Presence and duration of atrial fibrillation detected by continuous monitoring: crucial implications for the risk of thromboembolic events
GL Botto, L Padeletti, M Santini… - Journal of …, 2009 - Wiley Online Library
… This may impact on the management of antiarrhythmic and antithrombotic therapy,
especially in patients with a moderate risk of embolic events. These patients constituted a large …
especially in patients with a moderate risk of embolic events. These patients constituted a large …
[HTML][HTML] Detection of occult atrial fibrillation in patients with embolic stroke of uncertain source: a work in progress
JG Andrade, T Field, P Khairy - Frontiers in Physiology, 2015 - frontiersin.org
… between duration of the atrial fibrillation episode and risk of … detecting occult or subclinical
atrial fibrillation, and the temporal proximity of device-detected atrial fibrillation to stroke events…
atrial fibrillation, and the temporal proximity of device-detected atrial fibrillation to stroke events…
Left atrial volume index is associated with cardioembolic stroke and atrial fibrillation detection after embolic stroke of undetermined source
K Jordan, S Yaghi, A Poppas, AD Chang, B Mac Grory… - Stroke, 2019 - Am Heart Assoc
… , but the association with embolic stroke mechanisms remains unknown. … embolic stroke
subtypes and atrial fibrillation (AF) detection on cardiac event monitoring in patients with embolic …
subtypes and atrial fibrillation (AF) detection on cardiac event monitoring in patients with embolic …
Device-detected atrial high rate episodes and the risk of stroke/thrombo-embolism and atrial fibrillation incidence: a systematic review and meta-analysis
… of stroke/Thromboembolic (TE) events and incident clinical Atrial Fibrillation (AF) … fibrillation
detected by continuous monitoring: crucial implications for the risk of thromboembolic events …
detected by continuous monitoring: crucial implications for the risk of thromboembolic events …
Embolic stroke of undetermined source and detection of atrial fibrillation on follow-up: how much causality is there?
… if AF episodes detected during follow-up are indeed causally associated with the index event,
… Second, we compared the long-term risk of stroke recurrence and peripheral embolism …
… Second, we compared the long-term risk of stroke recurrence and peripheral embolism …
相关搜索
- atrial fibrillation detection
- arterial embolic events atrial fibrillation duration
- fibrillation detection cryptogenic stroke
- fibrillation detection embolic stroke
- fibrillation detection undetermined source
- arterial embolic events antitachycardia pacemakers
- fibrillation detection rhythm monitoring strategies
- fibrillation detection ischemic stroke recurrence
- fibrillation detection biomarkers of atrial cardiopathy
- fibrillation detection retrospective multicenter observational study
- temporal relationship embolic events
- fibrillation detection cardiac monitoring
- fibrillation detection left atrial volume index
- fibrillation detection prognosis of patients
- fibrillation detection meta analysis
- fibrillation detection systematic review