Extended application of percutaneous pulmonary valve implantation

TS Momenah, R El Oakley, K Al Najashi… - Journal of the American …, 2009 - jacc.org
Objectives : This study was designed to report a novel indication for percutaneous pulmonary
valve implantation in patients with previous right ventricular outflow tract (RVOT) patch. …

Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 1)

N Piazza, S Bleiziffer, G Brockmann, R Hendrick… - JACC: Cardiovascular …, 2011 - jacc.org
… Because transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation
represents a minimally invasive alternative to conventional redo surgery, it may prove to be safer …

Durability of prostheses for transcatheter aortic valve implantation

M Arsalan, T Walther - Nature Reviews Cardiology, 2016 - nature.com
… surgical and transcatheter aortic valves, and can extend the lifespan of bioprostheses … valve
implantation for failing surgical aortic bioprosthetic valve from concept to clinical application

Transcatheter aortic valve replacement: current application and future directions

AA Fassa, D Himbert, A Vahanian - Current cardiology reports, 2013 - Springer
… inoperable, indications for TAVR will likely be extended to a broader spectrum of patients,
in … to the double valve implantation and the durability of transcatheter valves in this setting. …

Application of tissue-engineering principles toward the development of a semilunar heart valve substitute

CK Breuer, BA Mettler, T Anthony, VL Sales… - Tissue …, 2004 - liebertpub.com
… elastin and collagen during valve motion. During opening, elastin extends at minimal load
… in tissue-engineered heart valves prepared in vitro and implanted in vivo are dynamic, and …

Transcatheter aortic valve implantation outcomes: implications for practice

ME McRae, M Rodger - Journal of Cardiovascular Nursing, 2012 - journals.lww.com
… procedure should not be extended to younger, healthy individuals until valve longevity is
known. … whether transcatheter valves show reduced durability in valve-in-valve applications. …

New advances in the prevention of transcatheter aortic valve implantation failure: current and future perspectives

F Piroli, L Franchin, F Bruno… - Polish Heart …, 2020 - journals.viamedica.pl
… improvements,3 TAVI indication has been extended to medium and low ‑risk pa‑ tients… valve
implantation crit‑ icalities have become of pivotal importance. Al‑ though bioprosthetic valves

Tissue engineered heart valves for transcatheter aortic valve implantation: current state, challenges, and future developments

N Poulis, P Zaytseva, EKN Gähwiler… - Expert review of …, 2020 - Taylor & Francis
… (6 weeks and 1 year after implantation) fatal failure in pediatric application [Citation92]. These
… durability and to better predict in-vivo tissue remodeling thereby extending the safety and …

Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves

H Eggebrecht, U Schäfer, H Treede… - JACC: Cardiovascular …, 2011 - jacc.org
Objectives : We sought to analyze outcomes of patients with degenerated surgically
implanted bioprosthetic heart valves undergoing valve-in-valve (viv) transcatheter aortic valve

Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort

R Gurvitch, DA Wood, EL Tay, J Leipsic, J Ye… - Circulation, 2010 - Am Heart Assoc
Background— Although short- and medium-term outcomes after transcatheter aortic valve
implantation are encouraging, long-term data on valve function and clinical outcomes are …