Brief report: point of care cryptococcal antigen screening: pipetting finger-prick blood improves performance of immunomycologics lateral flow assay
RM Wake, JN Jarvis, TS Harrison… - JAIDS Journal of …, 2018 - journals.lww.com
… , Norman, OK) CrAg lateral flow assay (LFA) using different techniques at point of care. …
study using the IMMY CrAg LFA on finger-prick blood. Accuracy, using direct application of LFA to …
study using the IMMY CrAg LFA on finger-prick blood. Accuracy, using direct application of LFA to …
Finger-Prick Whole Blood Cryptococcal Antigen Lateral Flow Assay for the Diagnosis of Cryptococcosis in HIV-Negative Patients: A Case Series Study in Two Tertiary …
JE Vidal, FG Oliveira, M Vieira, L Pereira… - Journal of Fungi, 2023 - mdpi.com
… of the finger-prick whole blood (point-of-care) cryptococcal antigen lateral flow assay (CrAg …
The objectives were to identify the sensitivity of a finger-prick whole blood CrAg LFA and to …
The objectives were to identify the sensitivity of a finger-prick whole blood CrAg LFA and to …
A serological assay to detect SARS-CoV-2 antibodies in at-home collected finger-prick dried blood spots
DG Karp, K Danh, NF Espinoza, D Seftel… - Scientific Reports, 2020 - nature.com
… by a healthcare worker either through phlebotomy or finger-prick. The need for in-person …
flow assays may at some point be approved for at-home testing. However, lateral flow tests …
flow assays may at some point be approved for at-home testing. However, lateral flow tests …
Diagnostic accuracy of point of care cryptococcal antigen lateral flow assay in fingerprick whole blood and urine samples for the detection of asymptomatic …
… The lateral flow assays on urine and fingerprick … The fingerprick whole blood sample was
collected by pricking the pad of the index finger with a lancet following sterilization of the finger …
collected by pricking the pad of the index finger with a lancet following sterilization of the finger …
A field method for cryopreservation of whole blood from a finger prick for later analysis with flow cytometry
AD Blackwell, AR Garcia… - American Journal of …, 2021 - Wiley Online Library
… sufficient blood sample from the finger prick to complete flow cytometry for both a fresh and at
… 3.2 Identification of lymphocyte subsets with flow cytometry Because our assay used whole …
… 3.2 Identification of lymphocyte subsets with flow cytometry Because our assay used whole …
Self-served and fully automated biochemical detection of finger-prick blood at home using a portable microfluidic analyzer
Y Zhu, X Meng, Y Chen, J Li, H Shao, Y Lu… - Sensors and Actuators B …, 2020 - Elsevier
… single-flow action does not mimic the multi-step procedures of laboratory-based assays that
… benchtop blood analyzer that can perform multiple assays with a single-use reagent disk, …
… benchtop blood analyzer that can perform multiple assays with a single-use reagent disk, …
High prevalence of Cryptococcal antigenemia using a finger-prick lateral flow assay in individuals with advanced HIV disease in Santarém Municipality, Brazilian …
JGPL Assy, RC Said, OC Pinheiro… - Medical …, 2021 - academic.oup.com
… The serum cryptococcal antigen (CrAg) lateral flow assay (LFA… of cryptococcal antigenemia
using finger-prick CrAg LFA in the … We tested CrAg LFA on finger-prick whole blood using an …
using finger-prick CrAg LFA in the … We tested CrAg LFA on finger-prick whole blood using an …
[HTML][HTML] Performance of five rapid serological tests in mild-diseased subjects using finger prick blood for exposure assessment to SARS-CoV-2
D Triest, L Geebelen, R De Pauw, S De Craeye… - Journal of Clinical …, 2021 - Elsevier
Objectives Assess the performance of five SARS-CoV-2 rapid serological tests (RST) using
finger prick (FP) blood on-site to evaluate their usability for exposure assessment in …
finger prick (FP) blood on-site to evaluate their usability for exposure assessment in …
P384 Therapeutic drug monitoring: performance of the first lateral flow-based Point of Care test for the quantification of infliximab in a finger prick
A Ametzazurra, J Pascual, L Del Rio… - Journal of Crohn's …, 2021 - academic.oup.com
… flow test (LFT) for the quantification of infliximab (IFX) in human whole blood (finger prick or
… Results: The linear assay range was determined to be 1-58 µg/mL in whole-blood and 0.6-…
… Results: The linear assay range was determined to be 1-58 µg/mL in whole-blood and 0.6-…
Integrated platform addressing the finger-prick blood processing challenges of point-of-care electrical biomarker testing
… flow assay principle, the inherent limited sensitivity and/or mostly qualitative nature of these
assays … to the feasibility of performing advanced bioanalytical assays in PoC settings. Among …
assays … to the feasibility of performing advanced bioanalytical assays in PoC settings. Among …
相关搜索
- lateral flow assay
- finger prick blood
- serological assay finger prick
- flow cytometry finger prick
- diagnosis of cryptococcosis finger prick
- quantification of infliximab finger prick
- cryopreservation of whole blood finger prick
- portable microfluidic analyzer finger prick
- two tertiary centers finger prick
- antigen screening finger prick
- antigen screening flow assay
- cryptococcal antigenemia finger prick
- brazilian amazon basin finger prick
- cryptococcal disease in patients flow assay
- continuum of hiv care flow assay
- cryptococcal antigen flow assay