A highly sensitive fluorometric assay for determination of human coagulation factor XIII in plasma

K Oertel, A Hunfeld, E Specker, C Reiff, R Seitz… - Analytical …, 2007 - Elsevier
… The assay was validated with respect to precision, detection … of the fluorometric assay with
the photometric assay for FXIII … suitability of the fluorometric assay for FXIII determination in …

[HTML][HTML] Protocols for enzymatic fluorometric assays to quantify phospholipid classes

S Morita, T Tsuji, T Terada - International journal of molecular sciences, 2020 - mdpi.com
fluorometrically detect enzymatically produced H 2 O 2 in the final steps. This section describes
several probes for detecting … for the enzymatic fluorometric assays for quantifying these …

Fluorometric assay for intestinal peptidases

JA Nicholson, TJ Peters - Analytical Biochemistry, 1978 - Elsevier
… the potentially carcinogenic chromogen o-dianisidine for detection of amino acids. … assay
than can be achieved by spectrophotometry. In a survey of substrates for the fluorometric

A fluorometric assay for acetylcholinesterase activity and inhibitor detection based on DNA-templated copper/silver nanoclusters

W Li, W Li, Y Hu, Y Xia, Q Shen, Z Nie, Y Huang… - Biosensors and …, 2013 - Elsevier
fluorometric assay for OPPs detection, we employed methamidophos to evaluate the viability
of this method to detect … fluorescent assay may have much potential for OPPs detection in …

Time-resolved fluorometric assay for detection of autoantibodies to glutamic acid decarboxylase (GAD65)

M Ankelo, A Westerlund-Karlsson, J Ilonen… - Clinical …, 2003 - academic.oup.com
… anti-human IgG in the detection step of the fluorometric assay, problems related to nonspecific
… Thus, in the fluorometric assay, the physicochemical conditions of the assay are closer to …

Fluorometric assay for measurement of viral neuraminidase—application to the rapid detection of influenza virus in nasal wash specimens

RH Yolken, VM Torsch, R Berg… - Journal of Infectious …, 1980 - academic.oup.com
A sensitive assay was developed for the measurement of neuraminidase with use of the 4-methylumbelliferyl-α-ketoside
of N-acetyl-neuraminic acid as a fluorescent substrate. …

Development and application of a fluorometric assay for mammalian membrane dipeptidase

SP Heywood, NM Hooper - Analytical biochemistry, 1995 - Elsevier
… In conclusion, we have developed a sensitive and rapid fluorometric-based detection system
for the assay of mammalian membrane dipeptidase by coupling the production of D-Phe to …

Fluorometric assay for alcohol sulfotransferase

WT Chen, MC Liu, YS Yang - Analytical biochemistry, 2005 - Elsevier
… In this study, we developed a continuous fluorometric AST assay whose sensitivity is
comparable to that of the end-point radioactive assay reported in the literature. This method was …

Evaluation of fluorometric and zymographic methods as activity assays for stromelysins and gelatinases

AR Quesada, M Mar Barbacid, E Mira… - Clinical & experimental …, 1997 - Springer
… the sensitivity of fluorometric assays, based on the degrada… detect MMP activity and in
this work both techniques were employed to compare their sensitivity with those of the fluorometric

Fluorometric assay for phospholipase A2 in serum.

T Thuren, JA Virtanen, M Lalla… - Clinical chemistry, 1985 - academic.oup.com
detection limit is approximately 6 pmol min1 mV1. Forty duplicate samples can be assayed
in … Here we describe a fluorometric assay, in which a fluorescent analog substrate of PLA2 is …