High-resolution separation of polychlorinated biphenyls by comprehensive two-dimensional gas chromatography

P Korytár, PEG Leonards, J De Boer… - … of Chromatography A, 2002 - Elsevier
… Comprehensive two-dimensional gas chromatography (GC×… polychlorinated biphenyl
congeners with emphasis on the separation of 12 toxic non- and mono-ortho chlorinated biphenyls

Gas chromatography-mass spectrometry method for identifying and determining polychlorinated biphenyls

GW Tindall, PE Wininger - Journal of Chromatography A, 1980 - Elsevier
… any of the 209 possible polychlorinated biphenyls (PCBs) in a … of any PCBs present by
computer control&d gas chromato… determination of PCBs and PCB mixtures in solid, gaseous, …

The application of gas chromatography to environmental analysis

FJ Santos, MT Galceran - TrAC Trends in Analytical Chemistry, 2002 - Elsevier
Nowadays, gas chromatography (GC) continues to play an important role in the identification
and quantification of ubiquitous pollutants in the environment. The present article describes …

Analysis of polychlorinated biphenyls (PCB) by glass capillary gas chromatography: Composition of technical Aroclor-and Clophen-PCB mixtures

K Ballschmiter, M Zell - Fresenius' Zeitschrift für analytische Chemie, 1980 - Springer
… high-resolution thin-film glass capillary gas chromatography with electron-capture detector.
… of their retention indices with those of polychlorinated biphenyls defined by synthesis or with …

Recent developments in the high-resolution gas chromatography of polychlorinated biphenyls

JW Cochran, GM Frame - Journal of Chromatography A, 1999 - Elsevier
… The interest in improving the gas chromatographic analysis of polychlorinated biphenyls (PCBs)
continues for several reasons. Unfortunately, one of the reasons is because they are …

Complete characterization of polychlorinated biphenyl congeners in commercial Aroclor and Clophen mixtures by multidimensional gas chromatography-electron …

DE Schulz, G Petrick, JC Duinker - Environmental Science & …, 1989 - ACS Publications
… Complete separation of congeners having identical retention times on SE-54 was obtained
with a multidimensional gas chromatographic technique. A total of 132 congeners were …

Characterization of polychlorinated biphenyl isomers in Sovol and Trichlorodiphenyl formulations by high-resolution gas chromatography with electron capture …

V Ivanov, E Sandell - Environmental science & technology, 1992 - ACS Publications
Since the discovery of polychlorinated biphenyls (PCBs) in environmental samples in 1966 (1),
it has been generally accepted that they are ubiquitous contaminants of every …

Comparison of gas chromatography and mineralization experiments for measuring loss of selected polychlorinated biphenyl congeners in cultures of white rot fungi

LA Beaudette, S Davies, PM Fedorak… - Applied and …, 1998 - Am Soc Microbiol
… the biodegradation of six polychlorinated biphenyl (PCB) … of the following congeners was
monitored by gas chromatography: 2,3-… Polychlorinated biphenyls (PCBs) are produced by …

Isotope dilution analysis of polychlorinated biphenyls (PCBs) in transformer oil and global commercial PCB formulations by high resolution gas chromatography–high …

T Takasuga, K Senthilkumar, T Matsumura, K Shiozaki… - Chemosphere, 2006 - Elsevier
… - through deca-chlorinated biphenyls was analyzed in order to accurately determine PCBs
by the isotope dilution technique using high resolution gas chromatography–high resolution …

… naphthalenes in polychlorinated biphenyl products via capillary gas chromatography—mass spectrometry after separation by gel permeation chromatography

P Haglund, E Jakobsson, L Asplund… - … of Chromatography A, 1993 - Elsevier
Gas chromatography (GC) was performed on a Varian Model 3700 gas chromatograph
equipped with an electron capture detector and a DB-5 fused-silica capillary column (30 m X …