Sensitivity of X-ray grating interferometry

P Modregger, BR Pinzer, T Thüring, S Rutishauser… - Optics express, 2011 - opg.optica.org
… It is known that the sensitivity of X-ray phase-contrast grating interferometry with regard to …
coherence or the number of phase step images. In particular, we identify the ideal inter-…

[HTML][HTML] Dual phase grating interferometer for tunable dark-field sensitivity

M Kagias, Z Wang, K Jefimovs… - Applied Physics Letters, 2017 - pubs.aip.org
… Hard X-ray dark-field and phase contrast imaging using grating interferometry have shown
great potential for medical and industrial applications. However, the wide spread applicability …

A four‐grating interferometer for x‐ray multi‐contrast imaging

H Miao, JC Williams Jr, D Josell - Medical Physics, 2024 - Wiley Online Library
imaging system but is technically challenging to produce for high x-ray energies. Phase-grating
interferometers … to introduce a four-grating x-ray interferometer that simultaneously allows …

Performance and optimization of X-ray grating interferometry

T Thuering, M Stampanoni - … Transactions of the Royal …, 2014 - royalsocietypublishing.org
… through increased image contrast between two materials. Using a grating interferometer,
the … Grating interferometry for multi-modal imaging recently gained considerable attention …

X-ray submicrometer phase contrast imaging with a Fresnel zone plate and a two dimensional grating interferometer

S Berujon, H Wang, I Pape, K Sawhney… - Optics Letters, 2012 - opg.optica.org
… are positioned parallel to the grating lines [10–… grating interferometer. We show that
the technique provides the spatial resolution that is obtained when working with absorption-contrast

High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry

J Vila-Comamala, L Romano, K Jefimovs, H Dejea… - Optics …, 2021 - opg.optica.org
… Typically, visibilities between 0.15 and 0.20 were obtained by our X-ray grating interferometer
and a total of 40000 photons were involved in the acquisition of the phase-stepping scans. …

Inverse geometry for grating-based x-ray phase-contrast imaging

T Donath, M Chabior, F Pfeiffer, O Bunk… - Journal of Applied …, 2009 - pubs.aip.org
… angle α ⁠, we utilize a Talbot grating interferometer comprising of an absorbing source …
arrangement, we have to choose the object position within the grating interferometer. In previous …

Application of X-ray grating interferometry for the imaging of joint structures

M Nagashima, J Tanaka, J Kiyohara… - Anatomical science …, 2014 - Springer
imaging. The basic concept of the X-ray phase-contrast imaging used in this study is similar
to that of differential interference contrast (Nomarski) microscopy. We applied Talbot–Lau X-…

Holotomography versus x-ray grating interferometry: A comparative study

I Zanette, S Lang, A Rack, M Dominietto… - Applied Physics …, 2013 - pubs.aip.org
… of phase-contrast imaging. … grating interferometer consists of two line gratings placed
between sample and detector (Fig. 1(b)). The first of these gratings, G1, typically a phase grating (…

Hard X-ray phase imaging and tomography using a grating interferometer

C David, T Weitkamp, F Pfeiffer, A Diaz, J Bruder… - … Acta Part B: Atomic …, 2007 - Elsevier
… We can derive two separate images of an object following a process described in more …
the amplitude contrast image that we would have received with no interferometer in the beam. It …