Advanced phase-contrast imaging using a grating interferometer
SA McDonald, F Marone, C Hintermüller… - Journal of …, 2009 - journals.iucr.org
… The phase grating is displaced transversely to the incident beam, along xg, over one grating
period whilst acquiring projections for at least four steps for an optimal sinusoidal curve. The …
period whilst acquiring projections for at least four steps for an optimal sinusoidal curve. The …
Low-dose, simple, and fast grating-based X-ray phase-contrast imaging
… Before positioning the sample, we scan the phase grating or the analyzer grating along the
transverse direction x g over one period of the analyzer grating and record the normalized …
transverse direction x g over one period of the analyzer grating and record the normalized …
Design, fabrication, and characterization of diffraction gratings for neutron phase contrast imaging
C Grünzweig, F Pfeiffer, O Bunk, T Donath… - Review of Scientific …, 2008 - pubs.aip.org
… (e) Profilometer scan over two grating periods denoting a structure height of 11.5μm
consisting of 1.3μm resist layer and the 10.2μm Gd absorption layer with a DC of 0.4. …
consisting of 1.3μm resist layer and the 10.2μm Gd absorption layer with a DC of 0.4. …
Noise in x‐ray grating‐based phase‐contrast imaging
T Weber, P Bartl, F Bayer, J Durst, W Haas… - Medical …, 2011 - Wiley Online Library
… to the measurements, while, in contrast, in this work, the data were … periods sampled by
the phase stepping has not necessarily to be an integer number of the analyser grating's period …
the phase stepping has not necessarily to be an integer number of the analyser grating's period …
Inverse geometry for grating-based x-ray phase-contrast imaging
T Donath, M Chabior, F Pfeiffer, O Bunk… - Journal of Applied …, 2009 - pubs.aip.org
… Recently, we have demonstrated this geometry for a π -shifting phase grating, for which
all grating periods including that of G1 become equal with p 0 = p 1 = p 2 . From the …
all grating periods including that of G1 become equal with p 0 = p 1 = p 2 . From the …
A grating‐based single‐shot x‐ray phase contrast and diffraction method for in vivo imaging
EE Bennett, R Kopace, AF Stein, H Wen - Medical physics, 2010 - Wiley Online Library
… grating-based phase contrast x-ray imaging method and demonstrate its capability ofin vivo
animal imaging… To quantify these changes, a second transmission grating of the same period …
animal imaging… To quantify these changes, a second transmission grating of the same period …
Designing the phase grating for Talbot-Lau phase-contrast imaging systems: a simulation and experiment study
… height simulation and measurement data show the subsequent behavior: For the grating
period of 2.185µm and grating heights below 6µm a higher duty cycle delivers a higher visibility…
period of 2.185µm and grating heights below 6µm a higher duty cycle delivers a higher visibility…
Grating interferometer based scanning setup for hard x-ray phase contrast imaging
C Kottler, F Pfeiffer, O Bunk, C Grünzweig… - Review of Scientific …, 2007 - pubs.aip.org
… image acquisition. Here, we report on an efficient scanning method for grating based x-ray
phase contrast imaging with … of the individual phase-stepping images. We find that the total …
phase contrast imaging with … of the individual phase-stepping images. We find that the total …
Fabrication of diffraction gratings for hard X-ray phase contrast imaging
C David, J Bruder, T Rohbeck, C Grünzweig… - Microelectronic …, 2007 - Elsevier
… of the three gratings. An example of an X-ray phase contrast image acquired with the grating
… p 0 and p 2 are the periods of the source grating and the analyzer grating, l is the source …
… p 0 and p 2 are the periods of the source grating and the analyzer grating, l is the source …
Quantitative x-ray phase-contrast imaging using a single grating of comparable pitch to sample feature size
… multiple exposures for image reconstruction. We present a simple method of single-exposure,
single-grating quantitative phase contrast for a regime in which the grating period is much …
single-grating quantitative phase contrast for a regime in which the grating period is much …
相关搜索
- x-ray phase contrast imaging
- phase contrast imaging techniques
- contrast imaging grating interferometer
- contrast imaging fabrication of diffraction gratings
- diffraction gratings neutron phase contrast imaging
- contrast imaging single absorption grating
- phase contrast imaging talbot interferometer
- contrast imaging sensitivity phase
- contrast imaging mechanical phase
- contrast imaging compact setup
- contrast imaging scanning mode
- phase contrast imaging dark field
- phase contrast imaging methods
- phase contrast imaging systems
- contrast imaging scanning setup
- phase contrast imaging high aspect ratios