Clinical evaluation of physician-controlled guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy (with video)

K Nishiguchi, T Ogura, N Nishioka… - Endoscopy …, 2021 - thieme-connect.com
… strategy regarding guidewire manipulation during EUS-HGS is as follows. If the guidewire is
… However, if guidewire manipulation proves unsuccessful even with PCGW, we change the …

Clinical evaluation of a newly developed guidewire for pancreatobiliary endoscopy

S Ishii, T Fujisawa, H Isayama, S Asahara… - Journal of Clinical …, 2020 - mdpi.com
… There were no adverse events related to GW manipulation in this study. The M-Through consists
of a soft tip with a hydrophilic … Therefore, we should manipulate this type of GW carefully. …

Magnetic versus manual guidewire manipulation in neuroradiology: in vitro results

T Krings, J Finney, P Niggemann, P Reinacher, N Lück… - Neuroradiology, 2006 - Springer
… be changed while the guidewire is in the vessel. We evaluated a novel magnetic navigation
… that can be used to reshape the guidewire tip in vivo without removing the wire from the …

Prospective evaluation of a treatment algorithm with enhanced guidewire manipulation protocol for EUS-guided biliary drainage after failed ERCP (with video)

DH Park, SU Jeong, BU Lee, SS Lee, DW Seo… - Gastrointestinal …, 2013 - Elsevier
evaluation of EUS-guided rendezvous and antegrade biliary stenting/balloon dilation with
our guidewire manipulation … This study also prospectively evaluated the learning curve of …

[PDF][PDF] Clinical evaluation of physician-controlled guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy (with video)

西口恭平, ニシグチキョウヘイ - ompu.repo.nii.ac.jp
… However, if guidewire manipulation proves unsuccessful even with PCGW, we … guidewire
or to a cystotome-guided guidewire technique might also be useful. However, if the guidewire

Histologic comparison of vibrating guidewire with conventional guidewire technique in an experimental coronary in vivo model

CS Katsouras, LK Michalis, VD Malamou-Mitsi… - Cardiovascular and …, 2003 - Springer
… to guidewire design and manipulation strategies. Our results demonstrate that both techniques
of guidewire manipulation … In conclusion, both methods of guidewire manipulation cause …

The evaluation of technical outcome and wire manipulation time within 30 min in patients with poor distal vessel quality on percutaneous coronary intervention for …

Y Ochiumi, Y Suzuki, A Murata, T Ito - Cardiovascular Intervention and …, 2021 - Springer
… The endpoint was also to establish a guidewire manipulation time within 30 min, as in the
J-… (3) For the guidewire manipulation time within 30 min for the J-CTO score, PDV was also an …

Vascular guide wire navigation with a magnetic guidance system: experimental results in a phantom

M Schiemann, R Killmann, M Kleen, N Abolmaali… - Radiology, 2004 - pubs.rsna.org
guide wire manipulation (P < .001) ( , Figs 9, , 10). The mean difference in procedure time,
as calculated with the Hodges-Lehmann estimator, was 19 seconds (95% CI: 11, 25 seconds)…

Fluoroscopic guide wire manipulation of malfunctioning peritoneal dialysis catheters initially placed by interventional radiologists

YH Kwon, SH Kwon, JH Oh, KH Jeong… - Journal of Vascular and …, 2014 - Elsevier
… In this study, we review our experience with fluoroscopic guide wire manipulation in patients
with malfunctioning PD catheters that were initially placed by interventional radiologists …

[引用][C] ID: 3527236 CLINICAL EVALUATION OF MODIFIED GUIDEWIRE MANIPULATION DURING EUS-GUIDED HEPATICOGASTROSTOMY

T Ogura, K Higuchi - Gastrointestinal Endoscopy, 2021 - giejournal.org
… Appropriate guidewire insertion is essential. Physician-controlled guidewire manipulation
(… The primary endpoint was the technical success rate of guidewire insertion into the common …