Comparison and improvement of the existing methods for the determination of aflatoxins in human serum by LC-MS/MS

A Santini, R Ferracane, G Meca, A Ritieni - Analytical Methods, 2010 - pubs.rsc.org
… volumes of human sera. AFB 1 has been extracted from 1 mL or less of human sera spiked
… to analyze feeds, foods and body fluids (human and animal plasma, serum, milk, etc.) The …

LCMS analysis of estradiol in human serum and endometrial tissue: Comparison of electrospray ionization, atmospheric pressure chemical ionization and …

P Keski‐Rahkonen, K Huhtinen, R Desai… - Journal of Mass …, 2013 - Wiley Online Library
LCMS assay sensitivity for E2 analysis, various approaches have been described. Sample
preparation and LC separation of steroids in biofluids such as serum … from human serum

Determination of doxazosin and verapamil in human serum by fast LCMS/MS: Application to document non-compliance of patients

L Chytil, B Štrauch, J Cvačka, V Marešová… - … of Chromatography B, 2010 - Elsevier
… Additionally, serum samples from patients receiving other medicaments commonly used for
… compounds in human serum, that can be analysed quantitatively by the LCMS/MS method …

Determination of essential amino acids in human serum by a targeting method based on automated SPE–LCMS/MS: discrimination between artherosclerotic patients

M Calderón-Santiago, F Priego-Capote… - … of pharmaceutical and …, 2012 - Elsevier
… The method optimized in this research was applied to human serum sampled from
individuals affected by atherosclerosis (n = 122), which is one of the most frequent causes of …

A simple and reliable bile acid assay in human serum by LCMS/MS

Y Shen, K Liu, X Luo, Q Guan… - Journal of Clinical …, 2022 - Wiley Online Library
… reliable LC-MS/MS method for the simultaneous determination of bile acids in human serum
… Improvements in comparison with previous LC-MS/MS methods were achieved regarding …

Quantitative analysis of thymosin α1 in human serum by LC-MS/MS

CW Tuthill, A Rudolph, Y Li, B Tan, TJ Fitzgerald… - Aaps Pharmscitech, 2000 - Springer
… in human serum was determined by solid phase extraction and reverse phase LCMS/MS. …
liquid chromatography (HPLC) system interfaced with the MS/MS system with a Turbo Ion …

Determination of nicotine and cotinine in human serum by means of LC/MS

F Baumann, R Regenthal, IL Burgos-Guerrero… - … of Chromatography B, 2010 - Elsevier
… The concentrations of nicotine and cotinine in human serum were determined during this
study period. These measured results served as control for the smoking behaviour and in future …

Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin

K Shibata, T Naito, J Okamura, S Hosokawa… - … of pharmaceutical and …, 2017 - Elsevier
… This study developed a simple and rapid LC-MS/MS method without immunopurification
using an immobilized trypsin for the absolute determination of cetuximab in human serum and …

Protein turnover measurements in human serum by serial immunoaffinity LC-MS/MS

V Farrokhi, X Chen, H Neubert - Clinical chemistry, 2018 - academic.oup.com
… We used a targeted mass spectrometry work flow based on serial immunoaffinity enrichment
ofmultiple human serum proteins from a [5,5,5- 2 H 3 ]-L-leucine tracer pulse-chase study in …

Determination of proline in human serum by a robust LCMS/MS method: application to identification of human metabolites as candidate biomarkers for esophageal …

S Liang, B Sanchez‐Espiridion, H Xie… - Biomedical …, 2015 - Wiley Online Library
… Altered serum proline levels are related to cancer metabolism. This study developed and
validated a LC-MS/MS method to analyze proline in human serum. Surrogate blank serum, …