Lung water assessment by lung ultrasonography in intensive care: a pilot study

G Baldi, L Gargani, A Abramo, L D'Errico… - Intensive care …, 2013 - Springer
… variables evaluated (weight and density) are not greatly influenced by these CT parameters.
… On the corresponding CT image (right), the portion of lung corresponding to the LUS image

Quantitative parametric perfusion images using 15O-labeled water and a clinical PET/CT scanner: test–retest variability in lung cancer

AAM van der Veldt, NH Hendrikse… - Journal of Nuclear …, 2010 - Soc Nuclear Med
… of parametric perfusion images. Methods: Eleven patients with non–small cell lung cancer
… blood volume parameter also improves the quality of parametric images. Consequently, the …

Measuring lung water: Ex vivo validation of multi‐image gradient echo MRI

S Holverda, RJ Theilmann, RC Sá… - … Resonance Imaging, 2011 - Wiley Online Library
… Sequence parameters were TR = 10 ms, flip angle = 10 deg, slice thickness = 15 mm, receiver
bandwidth = 125 kHz, and a full acquisition matrix of 64 × 64. Sequence parameters were …

Determination of lung water content and distribution by nuclear magnetic resonance imaging

AG Cutillo, AH Morris, DC Ailion… - … of Thoracic Imaging, 1986 - journals.lww.com
… of NMR imaging techniques is the determination of lung water content and distribution (water
ious NMR parameters to changes in lung Water Content would be of considerable inteest. …

[HTML][HTML] Imaging gravity-induced lung water redistribution with automated inline processing at 0.55 T cardiovascular magnetic resonance

F Seemann, A Javed, R Chae, R Ramasawmy… - Journal of …, 2022 - Elsevier
lung water measurements during exercise stress, we aimed to assess a regional redistribution
of lung water and therefore deployed our method to image … and imaging parameters as for …

Lung water estimation on cardiac magnetic resonance imaging for predicting adverse cardiovascular outcomes in patients with heart failure

M Verma, P Jagia, A Roy, PK Chaturvedi… - The British Journal of …, 2023 - academic.oup.com
images included short-axis slices, 2-chamber slices, 4-chamber slices with the following
parameters: … The imaging parameters included matrix size of 128 × 74 with a 360 × 270 mm field …

Ultrasound lung comets: a clinically useful sign of extravascular lung water

E Picano, F Frassi, E Agricola, S Gligorova… - Journal of the American …, 2006 - Elsevier
… It requires very basic 2-D technology imaging, even without a second … simple way to image
directly extravascular lung water. … 2 parameters, we can obtain the value of extravascular lung

Dynamic lung water MRI during exercise stress

F Seemann, A Javed, JM Khan… - Magnetic …, 2023 - Wiley Online Library
… with compensated heart failure to quantify lung water imaged during rest, exercise stress, …
more easily comprehendible parameter to visualize and compare lung water dynamics across …

[HTML][HTML] Lung imaging: how to get better look inside the lung

L Ball, V Vercesi, F Costantino… - Annals of …, 2017 - ncbi.nlm.nih.gov
… The extension of B-pattern images in the chest correlates … lung water measured with
transpulmonary thermodilution (35). … respiratory parameters, such as the end-expiratory lung

[HTML][HTML] Quantification of lung water in heart failure using cardiovascular magnetic resonance imaging

RB Thompson, K Chow, JJ Pagano, V Sekowski… - Journal of …, 2019 - Elsevier
… This included identical imaging parameters but the … lung water signal intensity [30, 31] we
only analyzed images at end-expiration. Future work will explore whether breath hold imaging