Effects of Implant Angulations and Attachment Configurations on the Retentive Forces of Locator Attachment–Retained Overdentures.

B Uludag, S Polat, V Sahin… - … & Maxillofacial Implants, 2014 - search.ebscohost.com
… type and design,21,22 component wear,23,24 and implant angulation.Predictably, … of
implant angulations and attachment configurations on the retentive forces of locator attachment– …

Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures: an in vitro study

SM Ortegón, GA Thompson, JR Agar, TD Taylor… - The Journal of prosthetic …, 2009 - Elsevier
… values when used with nonparallel implant configurations. … implant angulation and
retentiveness on parallel attachments. The functional rotational threshold of the Preci Clix …

Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element …

HR Hong, A Pae, Y Kim, J Paek… - … Implants, 2012 - search.ebscohost.com
… the effect of implant angulation, objective data were examined for implants inclined up to 15
… : Comparison between rigid and resilient attachment configurations. Med Eng Phys 2008;30:…

In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations

S Maniewicz, I Badoud, FR Herrmann… - Clinical oral implants …, 2020 - Wiley Online Library
… Statistical models demonstrated no effect of implant angulation on retention, except for 60
after … Angulations of 40 or higher were shown to lead to lower retentive forces (0 vs. 40 cycle …

The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system

SA Al-Ghafli, KX Michalakis, H Hirayama… - Journal of Prosthetic …, 2009 - thejpd.org
… The present in vitro study investigated the effect of implant angulation and cyclic … attachments.
The results of this study indicate that implant angulations negatively affect the attachment

Effect of implant angulation upon retention of overdenture attachments

MP Gulizio, JR Agar, JR Kelly… - … Prosthodontics: Implant …, 2005 - Wiley Online Library
implants depend upon mechanical components to provide retention. Ball attachments are
… , but retentive capacity of these components may be altered by a lack of implant parallelism. …

Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments – an in vitro study

M Srinivasan, M Schimmel, I Badoud… - Clinical oral implants …, 2016 - Wiley Online Library
… Two configurations are available, D20 and D60. SFI-Anchor ® D20 (Ø5.3mm × h2.5 mm)
is … ® attachment, that is, the implant angulation (up to 60) has no effect on this attachment's

Retention of implant‐supported overdentures at different implant angulations: Comparing Locator and ball attachments

N Sultana, DW Bartlett… - Clinical oral implants …, 2017 - Wiley Online Library
implant angulation on the retention of implant-supported overdentures by comparing the
Locator and ball attachment … that in both settings (0 and 20) the Locator attachment had a faster …

Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy.

ZF Akalin, YK Ozkan, A Ekerim - … Oral & Maxillofacial Implants, 2013 - search.ebscohost.com
… According to the results of the present study, as implant angulations increase, distortion in
… Especially in multiple-implant cases, an increase in implant angulations increases the area …

Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forces

TC Yang, Y Maeda, T Gonda… - Clinical oral implants …, 2011 - Wiley Online Library
… to the implant inclination. In the present study, the unsplinted anchorage attachments used
in mandibular single and two-implant … as the angulations increased among all attachments, …