[HTML][HTML] A mesh nebulizer is more effective than jet nebulizer to nebulize bronchodilators during non-invasive ventilation of subjects with COPD: A randomized …
VC Galindo-Filho, L Alcoforado, C Rattes, DN Paiva… - Respiratory …, 2019 - Elsevier
… jet nebulizer operating with oxygen at 8 lpm during NIV. Radiolabeled bronchodilators (fill
volume of 3 mL: 0.5 mL salbutamol 2.5 mg + 0.125 mL ipratropium 0.25 mg and physiologic …
volume of 3 mL: 0.5 mL salbutamol 2.5 mg + 0.125 mL ipratropium 0.25 mg and physiologic …
Comparison of vibrating mesh and jet nebulizers during noninvasive ventilation in acute exacerbation of chronic obstructive pulmonary disease
SN Avdeev, GS Nuralieva, AK Soe… - Journal of Aerosol …, 2021 - liebertpub.com
… have improved drug delivery efficiency during noninvasive ventilation (NIV). Clinical …
administered through a vibrating mesh nebulizer (VMN) and jet nebulizer (JN) during NIV in …
administered through a vibrating mesh nebulizer (VMN) and jet nebulizer (JN) during NIV in …
Radioaerosol pulmonary deposition using mesh and jet nebulizers during noninvasive ventilation in healthy subjects
VC Galindo-Filho, ME Ramos, CSF Rattes… - Respiratory …, 2015 - rc.rcjournal.com
… nebulizer was more efficient than the jet nebulizer, with counts higher for both lungs in the NIV
+ vibrating mesh nebulizer group compared with the NIV + jet nebulizer group… jet nebulizer …
+ vibrating mesh nebulizer group compared with the NIV + jet nebulizer group… jet nebulizer …
Effect of jet nebulization on noninvasive positive-pressure ventilation administered with noninvasive or intensive care unit ventilators: a bench study
MJ Xu, B Dai, Y Peng, J Su, W Tan, HW Zhao - Respiration, 2019 - karger.com
… ), T trig (time to trigger), and P trig (the magnitude of airway pressure drop needed to trigger)
were not significantly altered by jet nebulization in the noninvasive ventilators, while they …
were not significantly altered by jet nebulization in the noninvasive ventilators, while they …
Delivered dose with jet and mesh nebulisers during spontaneous breathing, noninvasive ventilation and mechanical ventilation using adult lung models
A Ari, JB Fink - ERJ Open Research, 2021 - Eur Respiratory Soc
… ventilation was found when the jet nebuliser … nebuliser up to three-fold greater than a jet
nebuliser during MV, NIV, and SB. In our previous in vitro research on the influence of nebuliser …
nebuliser during MV, NIV, and SB. In our previous in vitro research on the influence of nebuliser …
… and optimization of nebulizers' performance in non-invasive ventilation using different fill volumes: comparative study between vibrating mesh and jet nebulizers
… using input-variables including nebulizer-type [jet nebulizer (JN) and vibrating mesh nebulizer
(VMN)] fill-volumes of respirable dose placed in the nebulization chamber with an output-…
(VMN)] fill-volumes of respirable dose placed in the nebulization chamber with an output-…
[HTML][HTML] Effects of jet nebulization on ventilator performance with different invasive ventilation modes: a bench study
X Li, W Tan, H Zhao, W Wang, B Dai, H Hou - Frontiers in Medicine, 2022 - frontiersin.org
… ventilators. Therefore, here, we comprehensively investigated the effects of jet nebulization
on ventilator … of ICU ventilator (three of which were equipped with nebulization functions) with …
on ventilator … of ICU ventilator (three of which were equipped with nebulization functions) with …
In Vitro Comparison of Five Nebulizers During Noninvasive Ventilation: Analysis of Inhaled and Lost Doses
JB Michotte, E Jossen, J Roeseler, G Liistro… - Journal of aerosol …, 2014 - liebertpub.com
… of noninvasive ventilation, we compared inhaled and lost doses of three nebulizer systems
… drug delivery for the jet nebulizer. Concerning the ultrasonic device coupled with a bilevel …
… drug delivery for the jet nebulizer. Concerning the ultrasonic device coupled with a bilevel …
Effects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study
… during non-invasive ventilation (NIV). Our aim was to investigate, using a bench-top model,
the effect of different ventilator settings and positions of the exhalation port and nebulizer on …
the effect of different ventilator settings and positions of the exhalation port and nebulizer on …
Quantifying Delivered Dose with Jet and Mesh Nebulizers during Spontaneous Breathing, Noninvasive Ventilation, and Mechanical Ventilation in a Simulated …
A Ari, JB Fink - Pharmaceutics, 2021 - mdpi.com
… and SB with both jet and mesh nebulisers, … jet nebulizer (JN), and mesh nebulizer (MN)
during spontaneous breathing (SB), noninvasive ventilation (NIV), and mechanical ventilation …
during spontaneous breathing (SB), noninvasive ventilation (NIV), and mechanical ventilation …