T2-weighted lung imaging using a 0.55-T MRI system

AE Campbell-Washburn, AA Malayeri… - Radiology …, 2021 - pubs.rsna.org
… No compensation for cardiac motion was applied in this study, and artifacts are visible on
some lung images. Our prototype 0.55-T MRI system used custom receiver coils with limited …

Oxygen‐enhanced functional lung imaging using a contemporary 0.55 T MRI system

…, A Javed, MY Chen, T Benkert… - NMR in …, 2021 - Wiley Online Library
… oxygen-enhanced pulmonary imaging at 0.55 T with 3D stack-of-spirals ultrashort-T E (UTE) …
Recently, we described a 0.55 T MRI configuration with contemporary hardware and …

High-performance 0.55-T lung MRI in patient with COVID-19 infection

AE Campbell-Washburn, AF Suffredini, MY Chen - Radiology, 2021 - pubs.rsna.org
… in lung MRI and can also help increase MRI accessibility (4). Our study demonstrated the
capability of this MRI system configuration, compared with that of CT, for imaging COVID-19. …

Assessment of lung structure and regional function using 0.55 T MRI in patients with lymphangioleiomyomatosis

…, M Lowery, J Henry, C Mancini, T Machado… - … radiology, 2022 - journals.lww.com
lung imaging on a prototype low-field (0.55 T) MRI system in 65 patients with LAM. T2-weighted
imaging was used for assessment of lunglung parenchyma occupied by cysts. Regional …

Lung nodule detection with modern low-field MRI (0.55 T) in comparison to CT

M Hinsen, AM Nagel, MS May… - … Radiology, 2024 - journals.lww.com
Lung nodule detection is primarily reserved for CT imaging, which … MRI of the lung at 0.55
T could be an alternative to CT imaging for detecting and measuring clinically relevant lung

Oxygen-Enhanced Lung Imaging in Patients with LAM Using a High-Performance 0.55 t MRI System

…, MY Chen, W Majeed, T Benkert… - … IMAGING, 2020 - atsjournals.org
… regional lung function, as measured by pulmonary function tests (… MRI to examine regional
lung function in patients with LAM. Methods An MRI system was modified to operate at 0.55T (…

Submillimeter lung MRI at 0.55 T using balanced steady‐state free precession with half‐radial dual‐echo readout (bSTAR)

G Bauman, NG Lee, Y Tian, O Bieri… - Magnetic Resonance …, 2023 - Wiley Online Library
… In this study, we demonstrated the feasibility of sub-millimeter lung imaging using respiratory
self-gated bSTAR MRI in human subjects on a 0.55 T MR-system. The bSTAR technique …

2019 American Thoracic Society BEAR cage winning proposal: lung imaging using high-performance low-field magnetic resonance imaging

AE Campbell-Washburn - … Journal of Respiratory and Critical Care …, 2020 - atsjournals.org
MRI system that integrates modern technology at 0.55 T and provides superior imaging quality
in the lung (… low-field MRI system configuration, paired with optimal imaging approaches, …

Self‐gated 3D stack‐of‐spirals UTE pulmonary imaging at 0.55 T

…, C Mancini, P Su, W Majeed, T Benkert… - Magnetic resonance …, 2022 - Wiley Online Library
… In this work, we demonstrate a robust high-resolution pulmonary imaging technique for 0.55T
systems, … Siemens participated in the modification of the MRI system from 1.5T to 0.55T. …

Opportunities in interventional and diagnostic imaging by using high-performance low-field-strength MRI

…, B Basar, DA Herzka, MS Hansen, T Rogers… - Radiology, 2019 - pubs.rsna.org
… We used paired Student t tests to compare lung signal … in T1 of lung tissue following oxygen
inhalation at 0.55 T and 1.5 T, … MRI system that combines low magnetic field strength (0.55 T