Morphologic characterization of pulmonary nodules with ultrashort TE MRI at 3T
…, HY Lee, H Koyama, T Yoshikawa… - American Journal of …, 2018 - Am Roentgen Ray Soc
… A previous report on the evaluation of subsolid pulmonary nodules using CT showed only a
… these nodules (κ = 0.55), thus putting agreement between UTE-MRI and CT to a similar level …
… these nodules (κ = 0.55), thus putting agreement between UTE-MRI and CT to a similar level …
Proton MRI of the lung: how to tame scarce protons and fast signal decay
A Voskrebenzev… - … of Magnetic Resonance …, 2021 - Wiley Online Library
… Computed tomography (CT)-like images allow the assessment of lung structure with high …
strength (0.55T) MR with high-performance hardware in comparison with a 1.5T scanner with …
strength (0.55T) MR with high-performance hardware in comparison with a 1.5T scanner with …
New clinical opportunities of low-field MRI: heart, lung, body, and musculoskeletal
… [62] compared lung nodule detection between 0.55 T MRI and CT. In 964 total nodules of
46 patients, MRI had 100% accuracy in detecting nodules of size ≥ 6 mm, 80% (159/200) for …
46 patients, MRI had 100% accuracy in detecting nodules of size ≥ 6 mm, 80% (159/200) for …
Magnetic resonance imaging of lung perfusion
, … for Pulmonary Functional Imaging (IWPFI … - … Resonance Imaging, 2024 - Wiley Online Library
… MP MRI was primarily developed for use at 1.5 T, but it has also shown promising preliminary
results at low field of 0.55 T where it benefits from the high SNR inherent to a bSSFP-…
results at low field of 0.55 T where it benefits from the high SNR inherent to a bSSFP-…
Pulmonary diffusing capacity: assessment with oxygen-enhanced lung MR imaging—preliminary findings
CJ Müller, M Schwaiblmair, J Scheidler, M Deimling… - Radiology, 2002 - pubs.rsna.org
… MR) lung imaging allows spatially resolved visualization of oxygen diffusion from the alveoli
into the capillaries of the lungs… a contrast agent in MR imaging of the lung. Use of molecular …
into the capillaries of the lungs… a contrast agent in MR imaging of the lung. Use of molecular …
Pulmonary 3 T MRI with ultrashort TEs: influence of ultrashort echo time interval on pulmonary functional and clinical stage assessments of smokers
…, M Nishio, H Koyama, T Yoshikawa… - … Resonance Imaging, 2014 - Wiley Online Library
… All pulmonary UTE-MR images were obtained with a 3.0 T MR scanner (Achieva 3.0 T; Philips
… The details of the parameters for the first scan (UTE-MRI A) were: TR 10 msec, TE 0.2, 0.7, …
… The details of the parameters for the first scan (UTE-MRI A) were: TR 10 msec, TE 0.2, 0.7, …
[HTML][HTML] The clinical use of lung MRI in cystic fibrosis: what, now, how?
… has been historically out of the scope of lung imaging because of technical difficulties … lung
MRI has not been reported yet. Moreover, reports have shown that, at a field strength of 0.55 T…
MRI has not been reported yet. Moreover, reports have shown that, at a field strength of 0.55 T…
3He Diffusion MRI of the Lung1
…, YV Chang, CK Choong, AL Sukstanskii, T Tanoli… - Academic radiology, 2005 - Elsevier
… average ADC values of 0.55 cm 2 /second, an increase of 175% over normal volunteers (10). …
lung imaging community has yet to decide the resolution required for useful lung images. …
lung imaging community has yet to decide the resolution required for useful lung images. …
Oxygen-enhanced MR ventilation imaging of the lung: preliminary clinical experience in 25 subjects
Y Ohno, H Hatabu, D Takenaka… - American Journal of …, 2001 - Am Roentgen Ray Soc
… MR ventilation imaging was applicable in patients with lung cancer and pulmonary
emphysema… Detailed correlation between oxygen-enhanced MR ventilation data and pulmonary …
emphysema… Detailed correlation between oxygen-enhanced MR ventilation data and pulmonary …
Quantification of Aortic and Pulmonary 2D Flow Measurements at Low Field Using a 0.55 T Scanner. Validation Against 1.5 T MRI Scanning
… scan. Scanning parameters are as included in table 1. Higher voxel size and increased slice
thickness were used to improve signal to noise in the 0.55T scanner. … and pulmonary flows. …
thickness were used to improve signal to noise in the 0.55T scanner. … and pulmonary flows. …