Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer

SA Nehmeh, YE Erdi, CC Ling, KE Rosenzweig… - Medical …, 2002 - Wiley Online Library
motion, in FDG-PET images, based on a group of phantom studies. Respiration gated-PET
a function of gate width, lesion size, and motion amplitude. Smearing is quantified by the ratio …

The CT motion quantitation of lung lesions and its impact on PET-measured SUVs

YE Erdi, SA Nehmeh, T Pan, A Pevsner… - Journal of Nuclear …, 2004 - Soc Nuclear Med
… of lower SUVs, the respiratory phase during CT transmission scanning needs to be
measured or lung motion has to be regulated for imaging lung cancer in routine clinical practice. …

Effects of lung motion and tracer kinetics corrections on PET imaging of pulmonary function

SM Mijailovich, S Treppo… - Journal of Applied …, 1997 - journals.physiology.org
… a/Q) by imaging the lungs with positron emission tomography (PET) during a constant-… PET
images of local Va/Qwhere lung motion artifact was eliminated by respiratory gating of image

… of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: methodology and comparison with respiratory gated PET

SA Nehmeh, YE Erdi, KE Rosenzweig… - Journal of Nuclear …, 2003 - Soc Nuclear Med
motion artifacts in PET images of lung cancer. The method is referred to as respiratory-correlated
dynamic PET (RCDPET). RCDPET enables the acquisition of 4-dimensional PET data …

Respiratory motion management in PET/CT: applications and clinical usefulness

L Guerra, ED Ponti, S Morzenti… - Current …, 2017 - ingentaconnect.com
… (2), a typical splitting artifact of a lung lesion on PET images is represented (section A).
When gating technique is applied (section B) the artifact is completely removed and the …

Local respiratory motion correction for PET/CT imaging: Application to lung cancer

F Lamare, H Fayad, P Fernandez, D Visvikis - Medical Physics, 2015 - Wiley Online Library
… synchronized gated PET images, and difficult to detect for all three motion models considered
in this work. This resulted in reduced efficiency in terms of motion compensation, as can be …

Practical PET respiratory motion correction in clinical PET/MR

R Manber, K Thielemans, BF Hutton… - Journal of nuclear …, 2015 - Soc Nuclear Med
PET data and that the clinical PET image quality can be improved using only a short additional
… present but there is a significant motion artifact at the lung–liver edge in the uncorrected …

Local motion correction for lung tumours in PET/CT—first results

RA Bundschuh, A Martínez-Möller, M Essler… - … and molecular imaging, 2008 - Springer
… As respiratory motion is affecting quantification of PET images, … motion correction using
list-mode data without increasing acquisition time or reduced signal-to-noise ratio of the images. …

Motion freeze for respiration motion correction in PET/CT: a preliminary investigation with lung cancer patient data

TC Huang, KT Chou, YC Wang… - BioMed research …, 2014 - Wiley Online Library
… The rebinned PET image by motion freeze approach was defined as PET MF . Quantitative
analysis was performed by comparing the SUV mean , SUV max⁡ , and tumor volume and …

Lung motion correction on respiratory gated 3-D PET/CT images

M Dawood, N Lang, X Jiang… - … on medical imaging, 2006 - ieeexplore.ieee.org
… Our idea is to use respiratory gating for obtaining relatively motion free images of the lungs
… To correct the lung motion on the images, we need images with as less motion as possible. …