[HTML][HTML] Respiratory motion reduction in PET/CT using abdominal compression for lung cancer patients

TC Huang, YC Wang, YR Chiou, CH Kao - PloS one, 2014 - journals.plos.org
… artifacts in PET/CT images of patients with lung tumors using … for lung radiation treatments
efficiently reduces motion … In this study, we demonstrated respiratory motion correction in PET/…

The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging

C Liu, LA Pierce II, AM Alessio… - Physics in Medicine & …, 2009 - iopscience.iop.org
… However, PET/CT imaging of the lung and abdomen region is generally affected by patient
… To investigate the tumor volume change in motion-blurred PET images, we used two …

Motion correction options in PET/MRI

C Catana - Seminars in nuclear medicine, 2015 - Elsevier
… proposed for deriving the motion field directly from the PET images. Similar to … , lung tissue
was either masked out to avoid introducing bias in the adjacent regions 80 or the lung motion

PET/CT imaging: effect of respiratory motion on apparent myocardial uptake

L Le Meunier, R Maass-Moreno… - Journal of nuclear …, 2006 - Springer
… tween the lung and soft tissue, such as the liver-lung interface.… , PET/CT shows great promise
for cardiac imaging. However, … be a respiratory motion mismatch between the PET data and …

Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging

G Chang, T Chang, T Pan, JW Clark Jr… - Medical …, 2010 - Wiley Online Library
motion artifacts and PVE in lung/thoracic PET/CT imaging. In PET/CT imaging, PET images
are usually much more blurred when compared to the corresponding CT images. This …

[HTML][HTML] Management of respiratory motion in PET/computed tomography: the state of the art

A Pepin, J Daouk, P Bailly, S Hapdey… - Nuclear medicine …, 2014 - journals.lww.com
… For example, upper areas of the lungs are less subject to motion … Inversely, PET images of
a moving uptake represent motion … , respiratory motion CT artifacts, and/or blurred PET images

Event-by-event continuous respiratory motion correction for dynamic PET imaging

Y Yu, C Chan, T Ma, Y Liu, JD Gallezot… - Journal of Nuclear …, 2016 - Soc Nuclear Med
… Using a previously reported level-set method (18) to segment target organs (subjects 1–7,
myocardium; subjects 8–11, pancreas; subject 12, tumor in lung) from gated images, we …

Respiratory motion compensation for PET/CT with motion information derived from matched attenuation-corrected gated PET data

Y Lu, K Fontaine, T Mulnix, JA Onofrey… - Journal of nuclear …, 2018 - Soc Nuclear Med
… was acquired at the end-expiration phase, the CTAC-based image shows the banana
artifact at the lung–liver and lung–spleen interfaces (black arrow) because of the mismatch …

[PDF][PDF] PET/CT in non-small-cell lung cancer: value of respiratory-gated PET

SM Larson, SA Nehmeh, YE Erdi… - Chang Gung medical …, 2005 - cgmj.cgu.edu.tw
… The objectives of the study were: (1) to correct for respiratory motion artifacts in PET
imaging; and (2) to match PET and CT phases for the purpose of improving the local co-registration …

Effect of motion on tracer activity determination in CT attenuation corrected PET images: a lung phantom study

A Pevsner, SA Nehmeh, JL Humm… - Medical …, 2005 - Wiley Online Library
… , and its dependence upon CT attenuation at different phases of the motion cycle. To …
determined from PET/CT images of a lung phantom at rest and under simulated respiratory motion. …