FDG imaging of lung nodules: a phantom study comparing SPECT, camera-based PET, and dedicated PET
RE Coleman, CM Laymon, TG Turkington - Radiology, 1999 - pubs.rsna.org
… data, the image quality and lesion detection rate in clinical studies may differ from those
obtained in our phantom study. The radioactivity concentrations used in our study were meant to …
obtained in our phantom study. The radioactivity concentrations used in our study were meant to …
Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study
J Wang, M Del Valle, M Goryawala, JM Franquiz… - Medical & biological …, 2010 - Springer
… study is to develop and validate a simple and practical solution to the problem of respiratory
motion for the precise interpretation and quantitation of 18 FDG uptake of lung PET images. …
motion for the precise interpretation and quantitation of 18 FDG uptake of lung PET images. …
Effect of motion on tracer activity determination in CT attenuation corrected PET images: a lung phantom study
… PET/CT images of a lung phantom at rest and under simulated respiratory motion. The NEMA
2001 IEC body phantom, … 37, 28, 22, 17, 13, and 10 mm, was used in this study. To mimic …
2001 IEC body phantom, … 37, 28, 22, 17, 13, and 10 mm, was used in this study. To mimic …
Design of an anthropomorphic PET phantom with elastic lungs and respiration modeling
… phantom for PET imaging that combines anatomic fidelity and a realistic breathing mechanism
with deformable lungs… to develop an anthropomorphic phantom for PET imaging, which …
with deformable lungs… to develop an anthropomorphic phantom for PET imaging, which …
What is the best way to contour lung tumors on PET scans? Multiobserver validation of a gradient-based method using a NSCLC digital PET phantom
M Werner-Wasik, AD Nelson, W Choi, Y Arai… - International Journal of …, 2012 - Elsevier
… In addition to further phantom studies, the GRADIENT method needs to be validated in actual
patient PET images. An ultimate validation of any tumor-contouring method would require …
patient PET images. An ultimate validation of any tumor-contouring method would require …
Effect of respiratory gating on quantifying PET images of lung cancer
SA Nehmeh, YE Erdi, CC Ling… - Journal of nuclear …, 2002 - Soc Nuclear Med
… lung 18 F-FDG PET images in synchronization with the respiratory motion to reduce smearing
due to breathing and improve quantitation of 18 F-FDG uptake in lung … Phantom studies …
due to breathing and improve quantitation of 18 F-FDG uptake in lung … Phantom studies …
… of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: methodology and comparison with respiratory gated PET
SA Nehmeh, YE Erdi, KE Rosenzweig… - Journal of Nuclear …, 2003 - Soc Nuclear Med
… This was shown in phantom studies, and feasibility was demonstrated in a single patient. …
-FDG PET imaging, the approach is applicable to any PET tracer. Phantom studies showed that …
-FDG PET imaging, the approach is applicable to any PET tracer. Phantom studies showed that …
PET-CT: accuracy of PET and CT spatial registration of lung lesions
… lung (8.33±5.05 mm) than in the right lung (6.25±3.92 mm) (P=0.059). In conclusion, with a
dedicated PET-CT scanner and this clinically practical imaging … phantom and the PET-CT soft…
dedicated PET-CT scanner and this clinically practical imaging … phantom and the PET-CT soft…
Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer
SA Nehmeh, YE Erdi, CC Ling, KE Rosenzweig… - Medical …, 2002 - Wiley Online Library
… The PET data are then acquired in synchronization with the respiratory motion. Reduction in
… investigated in both phantoms and patient studies. Phantom studies showed a dependence …
… investigated in both phantoms and patient studies. Phantom studies showed a dependence …
The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: A phantom study
… We propose a center of mass (CoM) lung tumor tracking algorithm using gated-PET images
… geometric accuracy of the proposed algorithm was quantified in a dynamic phantom study. …
… geometric accuracy of the proposed algorithm was quantified in a dynamic phantom study. …
相关搜索
- effect of motion lung phantom study
- respiratory gated pet images
- pet imaging of lung cancer
- malignant lung lesions fdg pet images
- dedicated pet phantom study
- lung tumors phantom study
- simulation study pet images
- effect of respiratory gating pet images
- dynamic phantom study fdg pet
- positron emission tomography phantom study
- motion correction pet images
- lung nodules phantom study
- respiratory motion artifacts in pet imaging
- dynamic phantom study upper torso
- dynamic phantom study small lesions
- quantitative parameters fdg pet images