[HTML][HTML] Assessing kidney graft viability and its cells metabolism during machine perfusion
MI Bellini, F Tortorici, MI Amabile… - International Journal of …, 2021 - mdpi.com
… , such as machine perfusion (MP), have been shown to improve graft function, especially in
kidneys … With poor organ quality being a major reason for kidneys not being transplanted, an …
kidneys … With poor organ quality being a major reason for kidneys not being transplanted, an …
[HTML][HTML] Analysis of machine perfusion benefits in kidney grafts: a preclinical study
N Vaziri, R Thuillier, FD Favreau, M Eugene… - Journal of translational …, 2011 - Springer
… Machine perfusion (MP) has potential benefits for marginal … to determine machine perfusion
benefits on kidney grafts. … We evaluated kidney grafts preserved in ViaspanUW or KPS …
benefits on kidney grafts. … We evaluated kidney grafts preserved in ViaspanUW or KPS …
[HTML][HTML] Metabolic needs of the kidney graft undergoing normothermic machine perfusion
AS Arykbaeva, DK de Vries, JB Doppenberg… - Kidney International, 2021 - Elsevier
… testing and viability enhancement of the perfused graft, the 4Rs: … ex situ hypothermic machine
perfusion for kidney grafts is … of (sub)normothermic machine perfusion (NMP). Although the …
perfusion for kidney grafts is … of (sub)normothermic machine perfusion (NMP). Although the …
[HTML][HTML] Ex-vivo Kidney Machine Perfusion: Therapeutic Potential
R Zulpaite, P Miknevicius, B Leber, K Strupas… - Frontiers in …, 2021 - frontiersin.org
… In this comprehensive review current state of evidence regarding ex-vivo kidney machine
perfusion and its capacity in kidney graft treatment is presented. Moreover, challenges in …
perfusion and its capacity in kidney graft treatment is presented. Moreover, challenges in …
Improved kidney graft function after preservation using a novel hypothermic machine perfusion device
MHJ Maathuis, S Manekeller, A van der Plaats… - Annals of …, 2007 - journals.lww.com
… the Groningen Machine Perfusion (GMP) system in a large animal model comparing
oxygenated HMP with CS in kidney transplantation. To detect the optimal perfusion pressures, we …
oxygenated HMP with CS in kidney transplantation. To detect the optimal perfusion pressures, we …
[HTML][HTML] Improved approach for normothermic machine perfusion of cold stored kidney grafts
C von Horn, T Minor - American Journal of Translational Research, 2018 - ncbi.nlm.nih.gov
… Machine perfusion of kidney grafts also offers some potential to serve as a tool for
evaluation of kidney grafts in order to reduce the uncertainty with respect to graft viability often …
evaluation of kidney grafts in order to reduce the uncertainty with respect to graft viability often …
Application of machine perfusion preservation as a viability test for marginal kidney graft
N Matsuno, O Konno, A Mejit, Y Jyojima, I Akashi… - …, 2006 - journals.lww.com
… , kidneys with 0.40–0.65 mL/min/g machine perfusion flow should be transplanted within
16–20 hr. We suggest that early and delayed graft function of kidneys … that perfusion flow is a …
16–20 hr. We suggest that early and delayed graft function of kidneys … that perfusion flow is a …
Clinical use of controlled oxygenated rewarming of kidney grafts prior to transplantation by ex vivo machine perfusion. A pilot study
H Zlatev, C von Horn, M Kaths, A Paul… - European Journal of …, 2022 - Wiley Online Library
… reperfusion of cold-stored grafts has been suggested to entail … rise of graft temperature
by ex-vivo machine perfusion has, … during isolated machine perfusion of the graft prior to …
by ex-vivo machine perfusion has, … during isolated machine perfusion of the graft prior to …
Hypothermic machine perfusion of kidney grafts: which pressure is preferred?
BM Doorschodt, M Schreinemachers… - Annals of biomedical …, 2011 - Springer
… perfusion pressure (PP) during machine perfusion (MP) on the preservation quality of kidney
grafts… Thereafter, kidneys were washed out followed by 20 h of MP at 25 mmHg (MP25, n = 7…
grafts… Thereafter, kidneys were washed out followed by 20 h of MP at 25 mmHg (MP25, n = 7…
Ex vivo machine perfusion for renal graft preservation
JM Kaths, A Paul, LA Robinson, M Selzner - Transplantation Reviews, 2018 - Elsevier
… improve the outcome of marginal kidney grafts. This review summarizes … machine perfusion
studies, organized by temperature, and discusses potential future developments for graft …
studies, organized by temperature, and discusses potential future developments for graft …
相关搜索
- machine perfusion kidney graft viability
- normothermic machine perfusion kidney grafts
- pulsatile machine perfusion kidney graft
- hypothermic machine perfusion kidney grafts
- oxygenated machine perfusion kidney grafts
- machine perfusion kidney transplantation
- machine perfusion kidney transplant
- machine perfusion porcine kidneys
- ex-vivo machine perfusion kidney preservation
- machine perfusion preservation
- hypothermic machine perfusion cardiac death donors
- controlled oxygenated rewarming kidney grafts
- machine perfusion deceased donors
- machine perfusion benefits kidney grafts
- machine perfusion device kidney graft function
- therapeutic potential kidney machine perfusion