Effect of different bar attachment and clip materials on retention force for mandibular implant supported overdentures (an invitro study)
M AY Hammas, MG El-Saadawy… - Al-Azhar Dental Journal …, 2018 - journals.ekb.eg
… retentive characteristics of implant overdenture attachments … and the effects of fatigue on
material properties. Ultimately, short… The bar and clip attachment systems with different materials …
material properties. Ultimately, short… The bar and clip attachment systems with different materials …
Retention of bar clip attachment for mandibular implant overdenture
HI Nassar, MS Abdelaziz - BMC Oral Health, 2022 - Springer
… of retention after fatigue testing at different time intervals between two types of bar clip
materials (digitally designed PEEK bar clip and regular Nylon bar clip). Materials and methods …
materials (digitally designed PEEK bar clip and regular Nylon bar clip). Materials and methods …
Resilient liner vs. clip attachment effect on peri‐implant tissues of bar‐implant‐retained mandibular overdenture: a 1‐year clinical and radiographical study
MA Elsyad, AHEL Shoukouki - Clinical oral implants research, 2010 - Wiley Online Library
… peri-implant tissue health of mandibular overdentures retained to the implants using resilient
liner or clip … liner attachments were replaced and glazing material was reapplied 48 times. …
liner or clip … liner attachments were replaced and glazing material was reapplied 48 times. …
Rehabilitation with mandibular implant-retained complete overdenture using the association of two retention systems
VE de Souza Batista, FR de Souza Batista… - Journal of …, 2016 - journals.lww.com
… with two-implant-retained mandibular overdenture using bar/clip and ball attachment …
material (Impregum, 3 M ESPE) to obtain the working casts for two-implant-retained mandibular …
material (Impregum, 3 M ESPE) to obtain the working casts for two-implant-retained mandibular …
Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial
M Cune, F Van Kampen, A Van der Bilt… - The Journal of Prosthetic …, 2005 - Elsevier
… Materials and Methods: In a cross-over clinical trial, 18 edentulous patients with mandibular
denture complaints received two mandibular implants and new mandibular and maxillary …
denture complaints received two mandibular implants and new mandibular and maxillary …
The influence of clip material and cross sections of the bar framework associated with vertical misfit on stress distribution in implant-retained overdentures.
MBF dos Santos, A Bacchi… - International journal …, 2014 - search.ebscohost.com
… of bar attachments and clip materials used to retain overdentures. … and (2) different clip
materials do not influence the stress … of mandibular implants supporting an overdenture: Implant …
materials do not influence the stress … of mandibular implants supporting an overdenture: Implant …
Effect Of Three Different Bar Clip Materials on Retention of Implant-Supported Mandibular Overdenture: An Invitro Study
MH Selem, SA ElKady, IA El-asfahani - Egyptian Dental Journal, 2024 - journals.ekb.eg
… the PEEK and plastic clip materials showed significantly higher retention values
compared to zirconia clip materials when used with PEEK bar-retained mandibular implant-supported …
compared to zirconia clip materials when used with PEEK bar-retained mandibular implant-supported …
Retention and patient satisfaction with bar-clip, ball and socket and kerator attachments in mandibular implant overdenture treatment: An: in vivo: study
N Varshney, S Aggarwal, S Kumar… - The Journal of Indian …, 2019 - journals.lww.com
… and the excess material was trimmed … clip, ball and magnet attachments in mandibular
implant overdenture treatment: An in vivo comparison after 3 months of function Clin Oral Implants …
implant overdenture treatment: An in vivo comparison after 3 months of function Clin Oral Implants …
Prosthetic aspects and patient satisfaction with resilient liner and clip attachments for bar-and implant-retained mandibular overdentures: a 3-year randomized clinical …
MA ELsyad - International Journal of Prosthodontics, 2012 - search.ebscohost.com
… to the material from which the clips … -clip, ball and magnet attachments in mandibular implant
overdenture treatment: An in vivo comparison after 3 months of function. Clin Oral Implants …
overdenture treatment: An in vivo comparison after 3 months of function. Clin Oral Implants …
Retention and postinsertion maintenance of bar‐clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months …
F Van Kampen, M Cune, A Van Der Bilt… - Clinical oral implants …, 2003 - Wiley Online Library
… two permucosal implants in the inter-foramina region of the mandible, a … implant level and
spaces around the posts were created in the mandibular denture for the impression material…
spaces around the posts were created in the mandibular denture for the impression material…