Retention mechanisms and prosthetic complications of implant‐supported mandibular overdentures: long‐term results
A Dudic, R Mericske‐Stern - Clinical implant dentistry and …, 2002 - Wiley Online Library
… rates of mandibular implants supporting an overdenture, com… to the type of retention mechanism
for overdenture connection to … Seventy-five patients had a resilient retention device (ball …
for overdenture connection to … Seventy-five patients had a resilient retention device (ball …
A longitudinal study on mandibular implants supporting an overdenture: the influence of retention mechanism and anatomic-prosthetic variables on periimplant …
M Oetterli, P Kiener… - International Journal of …, 2001 - search.ebscohost.com
… often claimed that a resilient retention mechanism for overdenture fixation should be used to
… retention mechanism for overdenture fixation on the periimplant parameters of mandibular …
… retention mechanism for overdenture fixation on the periimplant parameters of mandibular …
The mandibular complete overdenture
DR Burns - Dental Clinics, 2004 - dental.theclinics.com
… the support and retention mechanism for mandibular overdenture treatment has occurred …
overdenture treatment provides many of the benefits of conventional tooth-borne overdentures …
overdenture treatment provides many of the benefits of conventional tooth-borne overdentures …
Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures
G Celik, B Uludag - The Journal of prosthetic dentistry, 2007 - Elsevier
… In the literature, applications of overdentures retained by 3 implants have also been reported…
to retain a mandibular overdenture in clinical situations that require increased retention, …
to retain a mandibular overdenture in clinical situations that require increased retention, …
Mandibular implant-retained overdentures: a literature review
SJ Sadowsky - The Journal of prosthetic dentistry, 2001 - Elsevier
… review of mandibular overdenture treatment concepts proposes that these concepts were
based on empirical data, and the use of a rigid versus moveable retention mechanism remains …
based on empirical data, and the use of a rigid versus moveable retention mechanism remains …
Retention characteristics of different attachment systems of mandibular overdentures retained by two or three implants.
… In addition to design, stability, and retention of the definitive … in the efficacy of implantretained
mandibular overdentures.Patient … retention mechanisms on 3-implant-retained mandibular …
mandibular overdentures.Patient … retention mechanisms on 3-implant-retained mandibular …
Early-loaded one-stage implants retaining mandibular overdentures by two different mechanisms: 5-year results.
K Akça, Y Çavuşoğlu, E Sağırkaya… - … journal of oral & …, 2013 - search.ebscohost.com
… retention. Recent evidence suggests that early and immediately loaded implants supporting
mandibular overdentures … the use of implant-supported mandibular overdentures, records of …
mandibular overdentures … the use of implant-supported mandibular overdentures, records of …
[PDF][PDF] Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features
MV Swain - Int J Prosthodont, 2009 - academia.edu
… factor for the loss of retention; however, the specific mechanisms involved in the wear … in
the retention and wear of attachment systems for mandibular two-implant overdentures are still …
the retention and wear of attachment systems for mandibular two-implant overdentures are still …
Maintenance requirements associated with mandibular implant overdentures: clinical results after first year of service
… On the other hand, in several clinical follow-up studies evaluating edentulous patients with
2 interforaminal implants, the retention mechanism of mandibular implants supporting an …
2 interforaminal implants, the retention mechanism of mandibular implants supporting an …
Influence of attachment wear on retention of mandibular overdenture
V Rutkunas, H Mizutani… - Journal of oral …, 2007 - Wiley Online Library
… Among all implant restorations, the loosening of overdenture retentive mechanisms has
been identified as the most common (33%) prosthodontic complication; therefore, routine …
been identified as the most common (33%) prosthodontic complication; therefore, routine …
相关搜索
- mandibular overdentures retention characteristics
- mandibular overdentures immediate loading
- mandibular overdentures prospective study
- mandibular overdentures retention and stability
- mandibular overdentures patient satisfaction
- three implant retained mandibular overdentures
- mandibular overdentures two different mechanisms
- mandibular overdentures retention forces
- two implant retained mandibular overdentures
- anterior mandible for overdentures
- retention mechanisms prosthetic complications
- mandibular overdentures two loading protocols
- mandibular overdentures endosteal implants
- retention mechanisms photoelastic stress analysis
- mandibular overdentures one or two implants
- mandibular overdentures influence of interimplant distance