Miniaturized fluorescence detection system to remove background noise of the incident light using micro mirror and lens

JM Jang, HJ Shin, SW Hwang, EG Yang… - Sensors and Actuators B …, 2005 - Elsevier
… This paper reports a study on the miniaturized fluorescence detection system using … of the
incident beam. Previous approaches were integrated optical fiber, inclined incident beam, and …

Miniaturization of fluorescence sensing in optofluidic devices

D Măriuţa, S Colin, C Barrot-Lattes, S Le Calvé… - Microfluidics and …, 2020 - Springer
miniaturization of fluorescence detection systems, emphasizing design and manufacturing
procedures, limits of detection … The incident light intersected the sample in the region of the …

A novel high-sensitive miniaturized optical system for fluorescence detection

M Yao, J Fang - … and Actuation for Biomedical Applications VIII, 2011 - spiedigitallibrary.org
… and miniaturized fluorescence detection system which integrated a LED light source, all …
-chip, portable bio-detection system and point-of-care diagnostic system. The prototype has …

A low-cost, low-power consumption, miniature laser-induced fluorescence system for DNA detection on a microfluidic device

S Shrinivasan, PM Norris, JP Landers… - Clinics in laboratory …, 2007 - Elsevier
… The photodiode transduced the incident light into a current, … signal (reflection of the laser
light from the glass microchip) while … The miniaturized detection system described in this report …

A low-cost light-emitting diode induced fluorescence detector for capillary electrophoresis based on an orthogonal optical arrangement

FB Yang, JZ Pan, T Zhang, Q Fang - Talanta, 2009 - Elsevier
… the complicated structure of the detection system or the energy loss of excitation light. In
this work, a miniaturized and low-cost LED-IF detector for CE system was developed based on …

Recent progress in portable fluorescence sensors

YH Shin, MT Gutierrez-Wing… - Journal of The …, 2021 - iopscience.iop.org
fluorescent microarray reader for point-of-care diagnostics 47 ; (b) a miniaturized fluorescence
(after 48 ); (c) a pocket-sized fluorescence detector for point-of-care testing using a paper-…

Miniaturized fluorescence excitation platform with optical fiber for bio-detection chips

H Yang, CT Lee, FY Chang - Microsystem technologies, 2007 - Springer
… The incident light and beam profiles were also examined for further study. This study shows
fluorescent detection method is a promised technique for miniaturized bio-detection systems. …

A facile light-emitting-diode induced fluorescence detector coupled to an integrated microfluidic device for microchip electrophoresis

F Yang, X Li, W Zhang, J Pan, Z Chen - Talanta, 2011 - Elsevier
detector is highly miniaturized. Instead, intersectant setup has also been used in the microchip
system. … 2.), as excitation source in our detection system. The choice was also because of …

Laser-induced fluorescence detection system for microfluidic chips based on an orthogonal optical arrangement

JL Fu, Q Fang, T Zhang, XH Jin, ZL Fang - Analytical chemistry, 2006 - ACS Publications
… and miniaturization of the optical system for confocal LIF systems … LIF detection systems
based on bevel incident laser or … coupling to chip-based systems, which have advantages of …

An integrated fluorescence detection system in poly (dimethylsiloxane) for microfluidic applications

ML Chabinyc, DT Chiu, JC McDonald… - Analytical …, 2001 - ACS Publications
… bias) on the power of the incident light. The dark count rate has been … density filters used to
reduce the power of the incident light. … could, in principle, be miniaturized. The benefits of this …