Monte Carlo characterization of skin doses in 6 MV transverse field MRI‐linac systems: effect of field size, surface orientation, magnetic field strength, and exit bolus
BM Oborn, PE Metcalfe, MJ Butson… - Medical …, 2010 - Wiley Online Library
… skin doses seen in MRI‐guided radiotherapy. In particular, the authors aim to characterize
the skin doses over a larger range of magnetic field strength and x‐ray field size than in the …
the skin doses over a larger range of magnetic field strength and x‐ray field size than in the …
MRI/linac integration
JJW Lagendijk, BW Raaymakers… - Radiotherapy and …, 2008 - Elsevier
… be an increase or a decrease depending on the magnetic field strength, electron energies,
field size, the obliquity of the interface and size of the gap compared to the helical path radius […
field size, the obliquity of the interface and size of the gap compared to the helical path radius […
Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with geant 4
… The choice of the aforementioned field sizes was made because our MRI Linac will focus
primarily on ablative SBRT type treatments where smaller field sizes will be used. …
primarily on ablative SBRT type treatments where smaller field sizes will be used. …
A high resolution 2D array detector system for small-field MRI-linac applications
M Gargett, B Oborn, SJ Alnaghy, T Causer… - Biomedical Physics …, 2018 - iopscience.iop.org
… does not significantly change the FWHM (≤0.1 mm), however there is an increase in
penumbral width, particularly on the right hand side of profiles for the smallest field sizes. As the …
penumbral width, particularly on the right hand side of profiles for the smallest field sizes. As the …
Comparison of treatment plans for a high-field MRI-linac and a conventional linac for esophageal cancer
… The remaining two cases had a longitudinal extension of 22.0cm and 22.6cm, respectively,
exceeding the maximum superior-inferior field size of 22cm of the MRI-linac. Plan realization …
exceeding the maximum superior-inferior field size of 22cm of the MRI-linac. Plan realization …
Experimental characterization of the dose deposition in parallel MRI‐linacs at various magnetic field strengths
J Begg, SJ Alnaghy, T Causer, T Alharthi… - Medical …, 2019 - Wiley Online Library
… film PDD collected on an Elekta linear accelerator in no magnetic field. The increase in dose
at … field, which was shown to increase with both field size and the magnitude of the magnetic …
at … field, which was shown to increase with both field size and the magnitude of the magnetic …
[HTML][HTML] Dosimetric optimization and commissioning of a high field inline MRI-linac
… field sizes set in the MLC control software had to be determined. It was obtained by the
measurement of the actual field sizes produced by a set of square fields … as nominal field sizes, …
measurement of the actual field sizes produced by a set of square fields … as nominal field sizes, …
[HTML][HTML] The impact of a 1.5 T MRI linac fringe field on neighbouring linear accelerators
T Perik, J Kaas, F Wittkämper - Physics and Imaging in Radiation Oncology, 2017 - Elsevier
… This study investigates the influence of an MRI linac fringe field on … after changes of the
magnetic field of the MRI linac. … neighbouring linacs and the MR-Linac determines the size of …
magnetic field of the MRI linac. … neighbouring linacs and the MR-Linac determines the size of …
Impact of the MLC on the MRI field distortion of a prototype MRI‐linac
… given field size at the isocenter decreases as the MLC and linac are positioned at larger SID.
Therefore, the MLC aperture was scaled inversely with increasing SID to keep the field size …
Therefore, the MLC aperture was scaled inversely with increasing SID to keep the field size …
Beam characterisation of the 1.5 T MRI-linac
SJ Woodings, JJ Bluemink, JHW De Vries… - Physics in Medicine …, 2018 - iopscience.iop.org
… MRI-linac penumbra (20%–80%) widths for each field edge for several standard field sizes
are … Also shown is a comparison between the MRI-linac and an Agility 6 MV FFF beam, …
are … Also shown is a comparison between the MRI-linac and an Agility 6 MV FFF beam, …
相关搜索
- mri linacs field strengths
- mri linac field variation
- high field inline mri linac
- mri linac effect of field size
- magnetic field mri linac dosimetry
- elekta unity mri linac
- 1.5 t mri linac accelerator component
- 1.5 t mri linac beam characterisation
- 1.5 t mri linac clinical proof
- mri linac open bore
- mri linac transformative technology
- mri linac array detector system
- mri linac radiation therapy dosimetry
- mri linac comparison of treatment plans
- mri linacs various magnetic field strengths
- skin doses effect of field size