Validity of measurement of shear modulus by ultrasound shear wave elastography in human pennate muscle
… shear modulus measurements in muscle. As previously described in detail [3,5], the ultrasound
shear wave elastography … an acoustic radiation force to perturb muscle tissues. The beam …
shear wave elastography … an acoustic radiation force to perturb muscle tissues. The beam …
Limitations of muscle ultrasound shear wave elastography for clinical routine—positioning and muscle selection
A Romano, D Staber, A Grimm, C Kronlage… - Sensors, 2021 - mdpi.com
… Shear wave elastography (SWE) is a clinical ultrasound imaging modality that enables
non-… of muscle and changes in elasticity due to passive muscle stretch—can confound muscle …
non-… of muscle and changes in elasticity due to passive muscle stretch—can confound muscle …
Validation of shear wave elastography in skeletal muscle
… Shear wave elastography (SWE) is an ultrasound-based … propagation of remotely induced
shear waves. The objective of … of skeletal muscle for three ultrasound transducer orientations. …
shear waves. The objective of … of skeletal muscle for three ultrasound transducer orientations. …
Muscle shear modulus measured with ultrasound shear‐wave elastography across a wide range of contraction intensity
Y Yoshitake, Y Takai, H Kanehisa… - Muscle & nerve, 2014 - Wiley Online Library
… the repeatability of measuring muscle shear modulus using ultrasound shear-wave
elastography between trials and between days, and the association between shear modulus and …
elastography between trials and between days, and the association between shear modulus and …
[HTML][HTML] Current status of musculoskeletal application of shear wave elastography
JA Ryu, WK Jeong - Ultrasonography, 2017 - ncbi.nlm.nih.gov
… Shear wave elastography is considered the most suitable type of US elastography for the …
The use of shear wave elastography to study muscles has increased exponentially in the …
The use of shear wave elastography to study muscles has increased exponentially in the …
… of tissue stiffness of the infraspinatus, erector spinae, and gastrocnemius muscle using ultrasound shear wave elastography and superficial mechanical deformation
JP Kelly, SL Koppenhaver, LA Michener… - Journal of …, 2018 - Elsevier
… ultrasound shear wave elastography (SWE) and superficial mechanical deformation (MyotonPRO)
in the infraspinatus, erector spinae, and gastrocnemius muscles… three muscle regions …
in the infraspinatus, erector spinae, and gastrocnemius muscles… three muscle regions …
Ultrasound shear wave elastography in assessment of skeletal muscle stiffness in senior volunteers
A Phan, J Lee, J Gao - Clinical imaging, 2019 - Elsevier
… We have demonstrated that ultrasound shear wave elastography is an effective resource to
establish quantifiable muscle stiffness and function in seniors. In our results, the difference in …
establish quantifiable muscle stiffness and function in seniors. In our results, the difference in …
Resting muscle shear modulus measured with ultrasound shear-wave elastography as an alternative tool to assess muscle fatigue in humans
J Siracusa, K Charlot, A Malgoyre, S Conort… - Frontiers in …, 2019 - frontiersin.org
… (VL) muscle shear elastic modulus (μ) measured with ultrasound shear-wave elastography
… of maximal voluntary fatiguing exercise of the KE muscles. The decrease of the resting VLμ …
… of maximal voluntary fatiguing exercise of the KE muscles. The decrease of the resting VLμ …
Measuring shear wave velocity in adult skeletal muscle with ultrasound 2-D shear wave elastography: a scoping review
ML Stiver, SA Mirjalili, AMR Agur - Ultrasound in medicine & biology, 2023 - Elsevier
… of “ultrasound shear wave elastography” and “skeletal muscle.” Records were limited in
the initial search to include those (i) involving human participants, and (ii) involving adult …
the initial search to include those (i) involving human participants, and (ii) involving adult …
[HTML][HTML] Non-invasive quantitative assessment of muscle force based on ultrasonic shear wave elastography
… shear wave elastography (SWE) to indirectly measure passive muscle force and to examine
the effects of muscle … from six muscles of four swine at different passive muscle loads under …
the effects of muscle … from six muscles of four swine at different passive muscle loads under …
相关搜索
- muscle stiffness ultrasound shear wave elastography
- gastrocnemius muscle ultrasound shear wave elastography
- muscle mechanics ultrasound shear wave elastography
- muscle injury ultrasound shear wave elastography
- muscle fatigue ultrasound shear wave elastography
- acquisition angles ultrasound shear wave elastography
- elbow position ultrasound shear wave elastography
- skeletal muscle shear wave elastography
- contraction intensity ultrasound shear wave elastography
- muscle shear wave elastography unit depth
- muscle force ultrasonic shear wave elastography
- supraspinatus muscle shear wave elastography
- muscle tissues shear wave elastography
- major muscles shear wave elastography
- lower limb muscles shear wave elastography
- different ultrasound machines shear wave elastography