Relationship between optical coherence tomography angiography vessel density and severity of visual field loss in glaucoma
… This study evaluates the relationship between OCT-A retinal vessel density parameters and
functional measurements and compares this with standard spectral-domain OCT (SD OCT) …
functional measurements and compares this with standard spectral-domain OCT (SD OCT) …
[HTML][HTML] Optical coherence tomography angiography vessel density in healthy, glaucoma suspect, and glaucoma eyes
A Yarmohammadi, LM Zangwill… - … & visual science, 2016 - tvst.arvojournals.org
… regard, optical coherence tomography angiography (OCT-A) … performance of OCT-A retinal
vessel density measurements for … spectral-domain (SD)-OCT RNFL thickness measurements. …
vessel density measurements for … spectral-domain (SD)-OCT RNFL thickness measurements. …
Macular vessel density measured with optical coherence tomography angiography and its associations in a large population-based study
… macular vessel density and demonstrated that a lower superficial retinal vessel density was
… , while a lower deep layer retinal vessel density was significantly associated with lower SSI, …
… , while a lower deep layer retinal vessel density was significantly associated with lower SSI, …
Regional comparisons of optical coherence tomography angiography vessel density in primary open-angle glaucoma
HL Rao, ZS Pradhan, RN Weinreb, HB Reddy… - American journal of …, 2016 - Elsevier
… and (Right) macular optical coherence tomography angiography images and the sectors
where vessel densities are calculated. The optic disc vessel density is calculated within the …
where vessel densities are calculated. The optic disc vessel density is calculated within the …
Repeatability of automated vessel density measurements using optical coherence tomography angiography
M Al-Sheikh, TC Tepelus, T Nazikyan… - British Journal of …, 2017 - bjo.bmj.com
Aims To determine the repeatability of optical coherence tomography angiography (OCT-A)-derived
automated vessel density measurements in the superficial retinal layer (SRL) and …
automated vessel density measurements in the superficial retinal layer (SRL) and …
Reproducibility of vessel density measurement with optical coherence tomography angiography in eyes with and without retinopathy
Q You, WR Freeman, RN Weinreb, L Zangwill… - Retina, 2017 - journals.lww.com
… The vessel density of the superficial and deep capillary … The vessel density was defined as
the proportion of vessel area … the superficial vessels, the accuracy of automated vessel density …
the proportion of vessel area … the superficial vessels, the accuracy of automated vessel density …
Vessel density of superficial, intermediate, and deep capillary plexuses using optical coherence tomography angiography
C Lavia, S Bonnin, M Maule, A Erginay, R Tadayoni… - Retina, 2019 - journals.lww.com
… Optical coherence tomography angiography with projection artifact removal can analyze
the … vessel density, a significant finding to evaluate retinal vascular diseases. Vessel density …
the … vessel density, a significant finding to evaluate retinal vascular diseases. Vessel density …
Vessel density, retinal thickness, and choriocapillaris vascular flow in myopic eyes on OCT angiography
P Milani, G Montesano, L Rossetti, F Bergamini… - Graefe's Archive for …, 2018 - Springer
… ) for the whole superficial vessel density (P = 0.006), but not … a lower whole superficial
vessel density (46.4 ± 4.9 vs.51.6 ± … vessel density (P < 0.0001, meaning that vessel density …
vessel density (46.4 ± 4.9 vs.51.6 ± … vessel density (P < 0.0001, meaning that vessel density …
Quantification of vessel density in retinal optical coherence tomography angiography images using local fractal dimension
SGK Gadde, N Anegondi, D Bhanushali… - … & visual science, 2016 - iovs.arvojournals.org
… dimension to calculate vessel density and FAZ area was demonstrated. Age did not impact
vessel density but sectoral analyses showed greater vessel density in the inferior zone. …
vessel density but sectoral analyses showed greater vessel density in the inferior zone. …
3D retinal vessel density mapping with OCT-angiography
… For localized vessel density analysis between longitudinal scans and across population, we
first calculate a vessel density image (VDI) that extends the information of the vessel mask to …
first calculate a vessel density image (VDI) that extends the information of the vessel mask to …
相关搜索
- oct angiography vessel density mapping
- optical coherence tomography angiography vessel density
- tomography angiography vessel density measurements
- tomography angiography vessel density inter-eye asymmetry
- tomography angiography vessel density glaucoma eyes
- tomography angiography vessel density regional comparisons
- tomography angiography vessel density assessment
- oct angiography retinal microvasculature
- tomography angiography vessel density field loss
- oct angiography myopic eyes
- primary open angle glaucoma vessel density
- structural measurements vessel density
- tomography angiography devices vessel density
- tomography angiography images vessel density
- oct angiography for the diagnosis
- pre-perimetric glaucoma retinal vessel density