The ocular effects of hyoscine-n-butylbromide (“Buscopan”) in radiological practice

GRJ Sissons, A McQueenie… - … British journal of radiology, 1991 - academic.oup.com
… regularly used in radiological and endoscopic procedures. One unwanted effect is temporary
… and repeated immediately before leaving the radiology department. Completed data was …

Ocular radiation exposure in modern urological practice

ER Taylor, B Kramer, TP Frye, S Wang… - The Journal of …, 2013 - auajournals.org
… Several studies have been done to determine the ocular … and found that the mean ocular
radiation exposure was 4,230 mSv. … urological practice is unlikely to reach this level of ocular

Ocular radiation exposure is negligible in normal volume endourological practice

J Peacock, J Henderson - The Annals of The Royal College …, 2024 - publishing.rcseng.ac.uk
… The aim of this study was to evaluate ocular radiation exposure in real-world practice. It is …
there is a need for protective ocular equipment in the form of mandatory lead-lined glasses. …

Ocular health among radiologists in the age of PACS: is it time for our profession to open its eyes to this issue in light of existing European legislation?

D Halpenny, D O'Driscoll… - … journal of radiology, 2012 - academic.oup.com
practice and to more broadly examine the issue of eye care as an occupational health issue
in radiology. … that their work practices reflect the legal situation and minimise the effect of eye …

[HTML][HTML] A review of non-cancer effects, especially circulatory and ocular diseases

MP Little - Radiation and environmental biophysics, 2013 - Springer
There is a well-established association between high doses (>5 Gy) of ionizing radiation
exposure and damage to the heart and coronary arteries, although only recently have studies …

Gantry angulation in brain CT: dosage implications, effect on posterior fossa artifacts, and current international practice.

LJ Yeoman, L Howarth, A Britten, A Cotterill, EJ Adam - Radiology, 1992 - pubs.rsna.org
The aim of this study was first to determine the effect of use of different scan planes at computed
… exists for a reduction in lens dose after reappraisal of radiologic practice in brain CT. …

Eye Lens Exposure to Radiation in Interventional Suites: Caution Is Warranted1

E Vano, L Gonzalez, JM Fernández, ZJ Haskal - Radiology, 2008 - pubs.rsna.org
… a dose effect threshold of less than 1 Gy. Thus, given that cataract is the dose-limiting ocular
… results of research performed with 59 practicing interventional radiologists who attended a …

THE ABCs OF RADIOLOGIC TESTING

J Fliegel, T Seng, S Weidmayer, K Lewis - Review of Optometry, 2018 - go.gale.com
… concerns that often hinder their use in optometric practice. … suspected or in cases of recent
ocular or orbital trauma; CT is … that often present with ocular manifestations. For example, in …

Cross-sectional imaging techniques in veterinary ophthalmology

D Penninck, GB Daniel, R Brawer, AS Tidwell - … in small animal practice, 2001 - Elsevier
ocular structures but offers limited information on the periocular tissues. CT and MRI provide
valuable morphologic and topographic images of both ocular … findings of ocular and orbital …

The lens of the eye: exposures in the UK medical sector and mechanistic studies of radiation effects

SD Bouffler, S Peters, P Gilvin, K Slack… - Annals of the …, 2015 - journals.sagepub.com
… The recommendation from the International Commission on Radiological Protection that the
… adequate protection of the eye while avoiding undesirable restrictions to working practices. …