Monitoring system for investigating the effect of temperature change on optical properties
… optical properties is needed for planning safer and more accurate laser treatments. A monitoring
system was developed to study how the optical properties … obtained optical properties, …
system was developed to study how the optical properties … obtained optical properties, …
Determination of optical properties in turbid medium based on time-resolved determination
D Qin, Z Ma, F Gao, H Zhao - Fifth International Conference on …, 2007 - spiedigitallibrary.org
… values of µs’ and µa of Intralipid-10%, and optical spectrometer can measure the µa of India
… the optical properties of commercially available Intralipid, thus the optical properties should …
… the optical properties of commercially available Intralipid, thus the optical properties should …
Detection of localized inclusions of gold nanoparticles in Intralipid-1% by point-radiance spectroscopy
S Grabtchak, TJ Palmer… - … of biomedical optics, 2011 - spiedigitallibrary.org
… Absorption and scattering coefficients of the system (Intralipid with Au NPs) can be
considered as a linear combination of the optical properties of the background medium (Intralipid) …
considered as a linear combination of the optical properties of the background medium (Intralipid) …
Improving the characterization of ex vivo human brain optical properties using high numerical aperture optical coherence tomography by spatially constraining the …
… However, the impact of TDE optical clearing via index matching on the optical property …
optical properties of the sample. We first evaluate our spatially parametrized model on Intralipid …
optical properties of the sample. We first evaluate our spatially parametrized model on Intralipid …
Measuring optical properties of clear and turbid media with broadband spectral interferometry
PNA Speets, J Kalkman - Applied Optics, 2023 - opg.optica.org
… for dilutions of glycerol, ethanol, and Intralipid 20% with water. Experiments were performed
with a … All optical properties could be retrieved from a single calibrated measurement of the …
with a … All optical properties could be retrieved from a single calibrated measurement of the …
Double-integrating-sphere system for measuring the optical properties of tissue
JW Pickering, SA Prahl, N Van Wieringen, JF Beek… - … optics, 1993 - opg.optica.org
… 1105) as a function of the distance from the sample (Intralipid-10%) and for three different
optical depths of the sample (τ = 5, 7, 10). At any given detector distance the higher the …
optical depths of the sample (τ = 5, 7, 10). At any given detector distance the higher the …
Static and dynamic light scattering properties of Intralipid aqueous suspension for tissue phantom preparation and calibration
I Delfino, R Esposito, B Piccirillo… - … with Optical …, 2008 - spiedigitallibrary.org
… Intralipid is a material widely employed for the preparation of phantoms simulating optical
properties of tissues in the field of optical imaging. Two main assumptions underlie the …
properties of tissues in the field of optical imaging. Two main assumptions underlie the …
Measurements of the scattering coefficients of intralipid solutions by a femtosecond optical Kerr gate
J Tong, Y Yang, J Si, W Tan, F Chen, W Yi… - Optical …, 2011 - spiedigitallibrary.org
… optical Kerr gate (OKG) in femtosecond time scale was used to determine the scattering
coefficients of intralipids, in … consisted of diluted Intralipid-20% solutions in an optical cell with the …
coefficients of intralipids, in … consisted of diluted Intralipid-20% solutions in an optical cell with the …
Shortwave infrared spatial frequency domain imaging for non-invasive measurement of tissue and blood optical properties
… for measuring the optical properties of subcutaneous tissue … on an analysis of optical
property uncertainties and imaging … intralipid to fabricate a skin mimicking phantom with optical …
property uncertainties and imaging … intralipid to fabricate a skin mimicking phantom with optical …
Optical properties and chromophore concentration measurements in tissue-like phantoms
E Drakaki, S Psycharakis, M Makropoulou… - Optics …, 2005 - Elsevier
… as the values reported by other research groups, are approximate values, due to variations
between samples over time, since Intralipid is a solution without standard optical properties. …
between samples over time, since Intralipid is a solution without standard optical properties. …