Optical properties of rat liver between 350 and 2200 nm

P Parsa, SL Jacques, NS Nishioka - Applied optics, 1989 - opg.optica.org
… Furthermore, if the intrinsic optical … of the optical properties of the liver over a wide spectral
range. The purpose of this study was to determine the intrinsic optical properties of the liver at …

Optical properties of rat liver and tumor at 633 nm and 1064 nm: photofrin enhances scattering

R Van Hillegersberg, JW Pickering… - Lasers in surgery …, 1993 - Wiley Online Library
… This article presents optical properties of rat liver and colon tumor at the relevant
wavelengths for PDT (around 630 nm) and thermal therapy (1,064 nm) in normal and Photofrin …

[PDF][PDF] Contribution of the mitochondrial compartment to the optical properties of the rat liver: a theoretical and practical approach

B Beauvoit, T Kitai, B Chance - Biophysical Journal, 1994 - cell.com
… to the optical properties, ie, light absorption and scattering, of the blood-free rat liver. Firstly,
a theoretical model of the reduced scattering coefficient of the liver was performed by using …

Microspectroscopic measurement of the optical properties of rat liver in the visible region

A Seiyama, SS CHEN, H Kosaka… - Journal of …, 1994 - Wiley Online Library
… We describe a simple method to estimate the optical properties of the liver using a … us (i)
to measure changes in optical densities (ODs) as a function of thickness of the intact liver, (ii) to …

Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm

JP Ritz, A Roggan, C Isbert, G Müller… - Lasers in Surgery …, 2001 - Wiley Online Library
… The aim of the present study was to determine the optical properties of liver tissue between
400 and 2400 nm and their … Optical properties of rat liver between 350 and 2200 nm. Appl …

Continuous measurement of the heat‐induced changes in the optical properties (at 1,064 nm) of rat liver

JW Pickering, P Posthumus… - Lasers in surgery and …, 1994 - Wiley Online Library
… A comparison of our results with optical properties of liver obtained from the literature [7-141 …
terms of the percentage change in the optical properties from the values measured prior to …

[HTML][HTML] Optical Properties of Perfused Rat Liver Tissues

K Kandurova, A Palalov, E Seryogina… - Journal of Biomedical …, 2023 - cyberleninka.ru
… In this work, we demonstrate the results of measuring the optical properties of rat liver tissue
slices after the liver itself underwent the perfusion procedure with an isotonic solution. The …

Optical properties of native and coagulated human liver tissue and liver metastases in the near infrared range

CT Germer, A Roggan, JP Ritz, C Isbert… - Lasers in Surgery …, 1998 - Wiley Online Library
… After measuring the optical properties in the native tissue state, each sample was
completely … Optical properties of rat liver between 350 and 2200 nm. Appl Opt 1989; 28:2325–2330. …

Experimental and analytical comparative study of optical coefficient of fresh and frozen rat tissues

M Mesradi, A Genoux, V Cuplov… - … of biomedical optics, 2013 - spiedigitallibrary.org
optical property measurements in rat organs. We measured the optical properties of fresh and
frozen rat … were used to derive optical properties for fresh rat liver at six wavelength points …

Femtosecond light distribution at skin and liver of rats: analysis for use in optical diagnostics

H Ullah, M Atif, S Firdous, MS Mehmood… - Laser Physics …, 2010 - iopscience.iop.org
… of tissue optical properties from diffusely reflected light from rat skin and liver to investigate …
There may be many more reasons for variation of µa and µs for rat liver and skin determined …