Effect of excitation wavelength on the separation of types I and III collagen by fiber optic fluorimetry

HJ Swatland - Journal of Food Science, 1987 - Wiley Online Library
… The optimum excitation wavelength for identification was 370 nm. Type IV (basement
membrane) collagen had a similar fluorescence to Type III collagen so that fluorescence from these …

Comparison of visible and near-infrared wavelength-excitable fluorescent dyes for molecular imaging of cancer

KE Adams, S Ke, S Kwon, F Liang… - … of biomedical optics, 2007 - spiedigitallibrary.org
excitation light 3 and the presence of tissue autofluorescence. The use of NIR-excitable
fluorescent dyes (with excitation at 780 … of backscattered excitation light is optimal for preventing …

Excitation wavelength analysis of laser-induced fluorescence LiDAR for identifying plant species

J Yang, W Gong, S Shi, L Du, B Zhu… - IEEE Geoscience and …, 2016 - ieeexplore.ieee.org
… sities on the fluorescence spectra excited by the 556-nm laser [20]. When the plant species
of the same genus were regarded as a category, the 355 nm was the most optimal EW in the …

The white confocal: continuous spectral tuning in excitation and emission

R Borlinghaus - Optical Fluorescence Microscopy: From the Spectral to …, 2010 - Springer
… the wavelength for optimal excitation, but also to record and evaluate sequences of τ-maps
against excitation wavelength. … lifetime and excitation color, which was not accessible by now. …

Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.

C Xu, W Zipfel, JB Shear… - Proceedings of the …, 1996 - National Acad Sciences
… For example, the optimal excitation wavelength of TPE FRET using fluorescein and rhodamine
is -920 nm (Fig. 2). Significantly better choices of donor and acceptor in TPE FRET would …

Raman spectroscopy at different excitation wavelengths (1064, 785 and 532 nm) as a tool for diagnosis of colon cancer

A Synytsya, M Judexova, D Hoskovec… - Journal of Raman …, 2014 - Wiley Online Library
… as optimal for measuring of fresh tissues due to relatively low background. By contrast, despite
increasing of signal intensity, excitation at shorter wavelengths … one excitation wavelength

An explicit estimated baseline model for robust estimation of fluorophores using multiple-wavelength excitation fluorescence spectroscopy

A Gautheron, M Sdika, M Hébert… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
… used in this study relies on multiple excitation wavelengths. The spectrally resolved signal of
… the least-square solution (αγ, bγ) for a given γ is first derived and then the optimal γ is found: …

Absolute two-photon absorption spectra and two-photon brightness of orange and red fluorescent proteins

M Drobizhev, S Tillo, NS Makarov… - The journal of …, 2009 - ACS Publications
… Table 2 presents the optimum excitation wavelength, corresponding absolute 2PA cross …
in two wavelength regions: 640−1000 and 1000−1100 nm. Fluorescence maximum wavelength

Ion yields in UV-MALDI mass spectrometry as a function of excitation laser wavelength and optical and physico-chemical properties of classical and halogen …

J Soltwisch, TW Jaskolla, F Hillenkamp… - Analytical …, 2012 - ACS Publications
Optimal use of multiply halogenated matrixes requires adjustment of the excitation wavelength
to values below that of the standard MALDI lasers emitting at 355 (Nd:YAG) or 337 nm (N …

Two‐photon fluorescence absorption and emission spectra of dyes relevant for cell imaging

F Bestvater, E Spiess, G Stobrawa… - Journal of …, 2002 - Wiley Online Library
… absorption spectra of the fluorochromes for optimal excitation of individual fluorophores in a
excitation wavelength for optimal power exploitation as well as for fluorescence excitation of …