[HTML][HTML] Paravalvular regurgitation after conventional aortic and mitral valve replacement: a benchmark for alternative approaches

BF Duncan, PM McCarthy, J Kruse, AC Andrei… - The Journal of Thoracic …, 2015 - Elsevier
Paravalvular regurgitation also may develop in patients undergoing percutaneous mitral
valve … occurrence of paravalvular regurgitation after conventional surgical valve replacement. …

Principles of percutaneous paravalvular leak closure

CS Rihal, P Sorajja, JD Booker, DJ Hagler… - JACC: Cardiovascular …, 2012 - jacc.org
… of a steerable sheath and a mechanical mitral valve with leaflets open. A single Amplatzer
… shows an en face view of the same prosthetic mitral valve (arrow). Arrowhead indicates the …

[HTML][HTML] Percutaneous complete repair of failed mitral valve prosthesis: simultaneous closure of mitral paravalvular leaks and transcatheter mitral valve implantation …

C Kliger, R Angulo, L Maranan… - …, 2015 - eurointervention.pcronline.com
Aims: Structural deterioration and paravalvular leak (PVL) are complications associated with
surgically implanted prosthetic valves, historically requiring reoperation. We present our …

Percutaneous closure of paravalvular leaks: a systematic review

I Cruz‐Gonzalez, JC Rama‐Merchan… - Journal of …, 2016 - Wiley Online Library
mitral valve as seen from the left atrial perspective, oriented in the surgical view. The aortic
valve is … The interatrial septum is located at 3 o'clock, and the posterior mitral annulus is at 6 o'…

The challenge of integrated echocardiographic approach in percutaneous closure of paravalvular leak

F Cappelli, MR Del Bene, G Santoro… - …, 2011 - Wiley Online Library
… We report on a case of dehisced prosthetic mitral valve in … mitral paraprosthesis leak,
whereas intracardiac echocardiography was used to guide and monitor the percutaneous closure

Percutaneous transcatheter closure of prosthetic mitral paravalvular leaks: are we there yet?

MS Kim, IP Casserly, JA Garcia, AJ Klein… - JACC: Cardiovascular …, 2009 - jacc.org
… (C) Real-time 3D TEE volumetric reconstruction demonstrating the anteromedial location
of the paravalvular defect (arrow) and mechanical mitral valve leaflets (arrowheads). IAS = …

Percutaneous Paravalvular Leak Closure–Imaging, Techniques and Outcomes–

A Krishnaswamy, SR Kapadia, EM Tuzcu - Circulation Journal, 2013 - jstage.jst.go.jp
… after mitral valve replacement (MVR) and in 1–5% after aortic … Percutaneous approaches
to PVL closure have therefore … the various techniques of percutaneous closure, and provide …

Percutaneous closure of mitral paravalvular leak: long-term results in a single-center experience

I Cruz-Gonzalez, P Luengo-Mondejar… - Journal of Clinical …, 2022 - mdpi.com
percutaneous closure alternatives for each individual patient. Included PVLs generated either
significant symptomatic mitral regurgitation or … , considering percutaneous closure. Patients …

Percutaneous mitral and aortic paravalvular leak repair: indications, current application, and future directions

RK Binder, JG Webb - Current cardiology reports, 2013 - Springer
… respect to valvular anatomy, typically viewing the mitral valve from a left atrial approach. …
the mitral valve as if viewed from the left atrium. When looking at the mitral valve, the aortic valve

Percutaneous device closure of paravalvular leak: combined experience from the United Kingdom and Ireland

PA Calvert, DB Northridge, IS Malik, L Shapiro… - Circulation, 2016 - Am Heart Assoc
… of PVLs of aortic and mitral valve replacements during device closure. A, … paravalvular leak.
For those patients who had a PVL leak of a single surgical valve, PVL leak of the mitral valve