Safety of transesophageal echocardiography to guide structural cardiac interventions

AB Freitas-Ferraz, M Bernier, R Vaillancourt… - Journal of the American …, 2020 - jacc.org
… , left atrial appendage closure, and paravalvular leak closure). … Transesophageal
echocardiography (TEE) has become an invaluable monitoring adjunct for operative and …

Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect

F Boccalandro, E Baptista, A Muench, C Carter… - The American journal of …, 2004 - Elsevier
… with TEE for guiding percutaneous closure of atrial septal defects. ICE had similar deployment
success rates and defect closure at … the TEE probe because the operator doing the closure

Percutaneous closure of atrial septal defects. The role of transesophageal echocardiography

SRF Pedra, CAC Pedra, JE Assef… - Arquivos Brasileiros …, 1999 - SciELO Brasil
… role of transesophageal echocardiography in percutaneous closure of … percutaneous
closure of ASD by means of the Amplatzer septal occluder is presented, stressing the role of TEE

Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions

G Perk, RM Lang, MA Garcia-Fernandez… - … of Echocardiography, 2009 - Elsevier
… We used RT3D TEE in 7 cases of percutaneous closure of a … However, more recently, the
successful percutaneous closureTEE in 2 patients who underwent the percutaneous closure of …

Utility of real-time three-dimensional transesophageal echocardiography in evaluating the success of percutaneous transcatheter closure of mitral paravalvular leaks

MA García-Fernández, M Cortés… - … of Echocardiography, 2010 - Elsevier
percutaneous surgery on periprosthetic dehiscences. Only two isolated cases of 3DTEE in
the percutaneous closure … most cases in which percutaneous closure of the dehiscence was …

Usefulness of transesophageal echocardiography in percutaneous transcatheter repairs of paravalvular mitral regurgitation

M Cortés, E García, MA García-Fernandez… - The American journal of …, 2008 - Elsevier
… From August 2003 to September 2006, 27 consecutive patients with mitral PVLs and
attempted percutaneous closure in the hemodynamic laboratory at our institution were …

Three-dimensional color Doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success

E Franco, C Almería, JA de Agustín, VA Del Val… - … of Echocardiography, 2014 - Elsevier
… the 3D transesophageal echocardiographic color-flow … percutaneous transcatheter PVL
closure procedures. All procedures were performed with 3D transesophageal echocardiographic

[PDF][PDF] The role of 3D transesophageal echocardiography during percutaneous closure of paravalvular mitral regurgitation

C Hamilton-Craig, T Boga, D Platts… - JACC: Cardiovascular …, 2009 - academia.edu
Transesophageal echocardiography (TEE) is used to assess the site and severity of paravalvular
MR before percutaneous closure … ) real-time transesophageal echocardiography (TEE) …

Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in …

ET Alboliras, ZM Hijazi - The American journal of cardiology, 2004 - Elsevier
… patients who had intracardiac echocardiographic guidance and 20 patients who had
transesophageal echocardiographic guidance during atrial septal defect closure were compared. …

Long-term transesophageal echocardiography follow-up after percutaneous left atrial appendage closure

S Staubach, L Schlatterbeck, M Mörtl, H Strohm… - Heart Rhythm, 2020 - Elsevier
… at long-term TEE ≥12 months after percutaneous LAA closure. Secondary outcome measures
were change in leak severity between 6-week TEE and long-term TEE, device thrombus, …