[PDF][PDF] Performance evaluation of a whole-body PET scanner using the NEMA protocol

G Brix, J Zaers, LE Adam, ME Bellemann… - Journal of Nuclear …, 1997 - Soc Nuclear Med
… -dimensional performance evaluation strictly after the revised version of the NEMA protocol
… , we followed the instruction of the NEMA protocol "to choose acquisition parameters as they …

Performance evaluation of the Vereos PET/CT system according to the NEMA NU2-2012 standard

I Rausch, A Ruiz, I Valverde-Pascual… - Journal of Nuclear …, 2019 - Soc Nuclear Med
… to evaluate the performance of a clinical installation of the Vereos PET/CT system according
to NEMA NU2-… protocol for the NEMA count rate performance test (NEMA-scatter.xml). The …

Performance evaluation of the Biograph mCT Flow PET/CT system according to the NEMA NU2-2012 standard

I Rausch, J Cal-González, D Dapra, HJ Gallowitsch… - EJNMMI physics, 2015 - Springer
… of the scatter fraction and count rate performance was used. The … the NEMA NU2-2012
protocol and reconstructed using the FORE FBP algorithm. Of note, the NEMA NU2-2012 protocol

NEMA NU2-2001 guided performance evaluation of four Siemens ECAT PET scanners

H Herzog, L Tellmann, C Hocke… - … on Nuclear Science, 2004 - ieeexplore.ieee.org
… According to the NEMA protocol, all counts were evaluated only within a diameter of 24 cm
and do not refer to the total field of view of the scanner. The scatter fraction was determined …

Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards

Q Bao, D Newport, M Chen, DB Stout… - Journal of Nuclear …, 2009 - Soc Nuclear Med
… This study evaluated the performance of the small-animal PET Inveon system based on
the new NEMA NU-4 protocol. Although direct comparison with previous results acquired with …

NEMA NU-4 performance evaluation of the IRIS PET/CT preclinical scanner

N Belcari, N Camarlinghi, S Ferretti… - … on Radiation and …, 2017 - ieeexplore.ieee.org
… The performance evaluation reported in this paper is made with non-rotating acquisition
scans only, as this modality is the one more commonly used in routine protocols. …

Performance evaluation of a PEM scanner using the NEMA NU 4—2008 small animal PET standards

W Luo, E Anashkin, CG Matthews - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
performance test protocols available, and the NU 2 protocol (… the PEM scanner, we decided
to evaluate the NU 4 Standards as an … The NEMA NU 4—2008 Standards were found to be a …

Performance evaluation of a newly developed high‐resolution, dual‐head animal SPECT system based on the NEMA NU1–2007 standard

V Moji, N Zeraatkar, MH Farahani… - Journal of applied …, 2014 - Wiley Online Library
… assessed the performance of the system based on NEMA-NU1–… The aim of this study was
the performance evaluation of a … The evaluation was based on the NEMA NU1–2007 protocol

Comparison of the performance evaluation of the MicroPET R4 scanner according to NEMA standards NU 4-2008 and NU 2-2001

FD Popota, P Aguiar, JR Herance… - … on Nuclear Science, 2012 - ieeexplore.ieee.org
NEMA published its NEMA NU 4-2008 standards, which provide a full protocol for the
performance evaluation … So far, not many scanners have been evaluated according to these …

NEMA NU‐4 2008 performance evaluation of Xtrim‐PET: A prototype SiPM‐based preclinical scanner

M Amirrashedi, S Sarkar, P Ghafarian… - Medical …, 2019 - Wiley Online Library
… We present the performance evaluation of the Xtrim-PET scanner following NEMA NU-4
2008 standards to help optimizing scanning protocols which can be achieved through standard …