Dose-rate conversion factors for external exposure to photons and electrons

DC Kocher - Health Physics, 1983 - journals.lww.com
dose-rate factors for photons were calculated for 21 separate body organs plus total body.
Dose-rate factors for electrons … external dose-rate conversion factors for photons and electrons

Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam

PW Hoban, M Heydarian, WA Beckham… - Physics in Medicine & …, 1994 - iopscience.iop.org
Dose rate dependence was not observed in electron depth-… diamond detector to changing
dose rate in a 6 MV linear accelerator photon beam is investigated. Both dose per pulse and …

The relative biological effectiveness of high-energy photons and electrons

WK Sinclair, HI Kohn - Radiology, 1964 - pubs.rsna.org
… of special note that the dose rates of the two beams should … to decrease noticeably as the
dose rate falls, for example, from … doses, detailed attention to the estimation of absorbed dose

Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV: EGS4 Monte Carlo model calculation

G Luxton, G Jozsef - Medical physics, 1999 - Wiley Online Library
… for tissuelike media and in particular, for water, calls for input from Monte Carlo models,
since complex multiparticle photonelectron Compton scattering cascades contribute a …

Electron dose rate and photon contamination in electron arc therapy

M Pla, EB Podgorsak, C Pla - Medical physics, 1989 - Wiley Online Library
electron dose rate at the depth of dose maximum d, and the photon contamination in rotational
electron … 4 where we plot the electron dose rate at d, and the corresponding photon dose

Dose-rate conversion factors for external exposure to photon emitters in soil

DC Kocher, AL Sjoreen - Health Physics, 1985 - journals.lww.com
… how dose-rate factors in air for monoenergetic photon sources are used to estimate dose-rate
External dose from electron emitters which are distributed in soil is not considered in this …

Absorbed dose rate conversion coefficients for reference terrestrial biota for external photon and internal exposures

V Taranenko, G Pröhl… - Journal of radiological …, 2004 - iopscience.iop.org
… absorbed dose per unit source strength for these targets is based on photon and electron
transport … The presented absorbed dose rate conversion coefficients are derived for terrestrial …

Dose-rate conversion factors for external exposure to photons and electrons

DC Kocher - 1980 - osti.gov
photons and electrons emitted by radionuclides dispersed in the environment. An external
dose-rate conversion factor, which we also call a doserate … a desired dose-equivalent rate for …

[PDF][PDF] Electron and photon beams from a 50 MeV racetrack microtron

A Brahme, T Kraepelien, H Svensson - Acta Radiologica …, 1980 - Taylor & Francis
photon beam combines the advantages of the photon beam … photon beam will also increase
the available dose rate since … 50 to 80 per cent of the photon fluence, is no longer needed. …

Photon absorbed dose standards

J Seuntjens, S Duane - Metrologia, 2009 - iopscience.iop.org
… absorbed dose standards for photon radiation therapy calibrations with typical dose rates of
a … Absorbed dose to water standards for photon and electron beams have been developed …