In vivo and post mortem measurements of the attenuation spectra of light in mammalian tissues
BC Wilson, WP Jeeves, DM Lowe - Photochemistry and …, 1985 - Wiley Online Library
… , these data showed that attenuation in vivo could be … to post mortem changes in optical
attenuation of tissues. If the changes are significant in the relevant regions of the visible spectrum …
attenuation of tissues. If the changes are significant in the relevant regions of the visible spectrum …
Postmortem imaging: MDCT features of postmortem change and decomposition
AD Levy, HT Harcke, CT Mallak - The American journal of forensic …, 2010 - journals.lww.com
… Knowledge of the spectrum of postmortem change and … mortis, and decomposition are post
mortem changes that begin to … with postmortem MDCT, intravascular high attenuation from …
mortem changes that begin to … with postmortem MDCT, intravascular high attenuation from …
Characterization of post mortem arterial tissue using time-resolved photoacoustic spectroscopy at 436, 461 and 532 nm
PC Beard, TN Mills - Physics in Medicine & Biology, 1997 - iopscience.iop.org
… The photoacoustic signatures generated in normal and atheromatous post mortem aorta
at 436, 461 and 532 nm are discussed in the following paragraphs. The effective attenuation …
at 436, 461 and 532 nm are discussed in the following paragraphs. The effective attenuation …
Diffusely decreased liver attenuation on post-mortem computed tomography: Comparison with ante-mortem computed tomography and autopsy findings
M Ishida, W Gonoi, G Shirota, H Okuma… - Journal of Forensic …, 2019 - Elsevier
… liver attenuation on post-mortem computed tomography (CT) which is lower than that on
ante-mortem CT. … We compared post-mortem CT (PMCT) liver attenuations with those on ante-…
ante-mortem CT. … We compared post-mortem CT (PMCT) liver attenuations with those on ante-…
Human skull translucency: post mortem studies
… of spectral … attenuation of light transmitted through a skull A = ln(I 0 /I 1 ) is linearly related
to its absorption coefficient μ a . Assuming that a mean value of the measured light attenuation …
to its absorption coefficient μ a . Assuming that a mean value of the measured light attenuation …
Estimation of postmortem interval in rat liver and spleen using Fourier transform infrared spectroscopy
P Huang, W Tian, Y Tuo, Z Wang, G Yang - Spectroscopy Letters, 2009 - Taylor & Francis
… [ Citation 1 ] Therefore, in this study we have applied FT-IR spectroscopy to detect the changes
of spectra quantitatively in rat liver and spleen and to evaluate its value for estimating PMI…
of spectra quantitatively in rat liver and spleen and to evaluate its value for estimating PMI…
Assessing various Infrared (IR) microscopic imaging techniques for post-mortem interval evaluation of human skeletal remains
… Mid infrared (MIR) reflection and ATR (Attenuated Total Reflection) microscopic … spectral
range from wave numbers of 4000 cm -1 to 600 cm -1 . Spectra were recorded with a spectral …
range from wave numbers of 4000 cm -1 to 600 cm -1 . Spectra were recorded with a spectral …
Modern post-mortem imaging: an update on recent developments
S Grabherr, C Egger, R Vilarino… - Forensic sciences …, 2017 - academic.oup.com
… the different degrees of tissue attenuation of X-rays from … spectroscopy to characterize
time-dependent cerebral metabolic changes in sheep [77]. This chemical study of the post-mortem …
time-dependent cerebral metabolic changes in sheep [77]. This chemical study of the post-mortem …
[HTML][HTML] The attenuation of selected soft tissue as a function of frequency
DH Le Croissette, RC Heyser… - Ultrasonic Tissue …, 1979 - books.google.com
… attenuation with frequency to give a more nearly constant signal-to-noise ratio over the selected
frequency spectrum… post-mortem (fresh),(c) fixed five hours postmortem, and (d) fixed five …
frequency spectrum… post-mortem (fresh),(c) fixed five hours postmortem, and (d) fixed five …
In vivo to post-mortem change in tissue penetration of red light
C Whitehurst, ML Pantelides, JV Moore, TA King… - Lasers in Medical …, 1990 - Springer
… between in vivo and post-mortem. Significant changes in … for in vivo measurements of
attenuation coefficients become … and post mortem measurements of the attenuation spectra of …
attenuation coefficients become … and post mortem measurements of the attenuation spectra of …
相关搜索
- post-mortem interval
- post-mortem imaging
- post-mortem computed tomography
- infrared spectroscopy post-mortem interval estimation
- post-mortem radiology
- post-mortem change
- histological analysis post-mortem computed tomography angiography
- micro-computed tomography post-mortem interval estimation
- mammalian tissues attenuation spectra
- imaging techniques post-mortem interval evaluation
- rat liver tissues post-mortem interval estimation
- infrared spectroscopy attenuated total reflection fourier
- mammalian tissues post mortem
- post mortem attenuation spectra forensics
- postmortem attenuation spectra
- post mortem attenuation spectra blood