Radiation exposure to cardiologists performing interventional cardiology procedures
M Delichas, K Psarrakos… - European journal of …, 2003 - Elsevier
… Medical doctors, who practice interventional cardiology, receive a noticeable radiation dose.
In this study, we measured the radiation dose to 9 cardiologists during 144 procedures (72 …
In this study, we measured the radiation dose to 9 cardiologists during 144 procedures (72 …
Radiation dose measurements to the interventional cardiologist using an electronic personal dosemeter
V Tsapaki, S Kottou, S Patsilinakos… - Radiation protection …, 2004 - academic.oup.com
… cardiologist in an Interventional Cardiology (IC) Laboratory of a busy cardiac centre and how
the results could help in the evaluation of radiation … Patient dose was measured with a dose-…
the results could help in the evaluation of radiation … Patient dose was measured with a dose-…
Patient radiation doses in interventional cardiology procedures
I Pantos, G Patatoukas, DG Katritsis… - Current cardiology …, 2009 - ingentaconnect.com
… for skin-dose measurements in interventional radiology: Validation of a dosimetric procedure
on a sample of patients undergone interventional cardiology. Phys Med 2006; 22: 105-10. …
on a sample of patients undergone interventional cardiology. Phys Med 2006; 22: 105-10. …
Occupational radiation doses in interventional cardiology: a 15-year follow-up
E Vano, L Gonzalez, JM Fernandez… - The British journal of …, 2006 - academic.oup.com
… radiation doses of interventional cardiologists over 15 years and assesses action undertaken
to optimize radiation … The dose measured by the dosemeter worn under the apron was 42 …
to optimize radiation … The dose measured by the dosemeter worn under the apron was 42 …
Staff radiation doses in interventional cardiology: correlation with patient exposure
… In pediatric interventional cardiology, cardiologists need to … biplane systems increases the
scatter radiation. Occupational … From these values and the radiation field size at the position …
scatter radiation. Occupational … From these values and the radiation field size at the position …
Patient radiation doses in paediatric interventional cardiology procedures: a review
RW Harbron, S Dreuil, MO Bernier… - Journal of …, 2016 - iopscience.iop.org
… Around half of reviewed publications did not mention calibration of dose measuring equipment
or quality assurance measures. Recorded P KA figures are subject to an uncertainty of …
or quality assurance measures. Recorded P KA figures are subject to an uncertainty of …
Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology
E Vano, L Gonzalez, JM Fernandez… - Radiation protection …, 2006 - academic.oup.com
… In this paper, scatter dose values measured at the typical position of the cardiologist during
procedures are reported for different patient thicknesses and for the different operational …
procedures are reported for different patient thicknesses and for the different operational …
Radiation dose and image quality for paediatric interventional cardiology
… modes and to avoid errors in dose measurements, images of the test object (to evaluate
image quality) were recorded simultaneously with the dose measurements. The acquisition and …
image quality) were recorded simultaneously with the dose measurements. The acquisition and …
Comparison of radiation dose to patient and staff for two interventional cardiology units: a phantom study
… the patient and staff dose during routine interventional cardiology procedures for an
image … In the present study, scattered radiation measurements showed that the operator-received …
image … In the present study, scattered radiation measurements showed that the operator-received …
A summary of recommendations for occupational radiation protection in interventional cardiology
A Duran, SK Hian, DL Miller, JL Heron… - Catheterization and …, 2013 - Wiley Online Library
… The radiation dose received by interventional cardiologists can vary … doses. There is particular
concern regarding occupational … Measurements of occupational doses are obtained using …
concern regarding occupational … Measurements of occupational doses are obtained using …
相关搜索
- radiation dose measurements electronic personal dosemeter
- interventional cardiology procedures
- interventional cardiology radiation protection
- patient radiation doses
- paediatric interventional cardiology
- image quality radiation dose
- radiation exposure cardiac catheterization
- interventional cardiology staff radiation doses
- occupational radiation doses
- interventional cardiology units radiation dose
- interventional examinations assessment of radiation doses
- interventional cardiology extremity exposure
- interventional cardiology patient and staff doses
- interventional cardiology patient dosimetry
- radiological exposure of patients invasive cardiology
- cardiology procedures radiation dose levels