Radiation doses to operators in hepatobiliary interventional procedures

S Degiorgio, R Gerasia, F Liotta, L Maruzzelli… - … Interventional Radiology, 2018 - Springer
… This study aims to provide a summary of estimated radiation doses received by operators
in different vascular and non-vascular hepatobiliary interventional procedures. The total dose

[HTML][HTML] Radiation dose to multidisciplinary staff members during complex interventional procedures

B Mussmann, TR Larsen, M Godballe, AJ Abdi… - Radiography, 2024 - Elsevier
… Complex interventional radiology procedures involve extensive fluoroscopy and image …
radiation dose is crucial in optimization. The purpose was to determine radiation doses received …

Radiation dose among different cardiac and vascular invasive procedures: the RODEO study

A Sciahbasi, G Ferrante, D Fischetti, DJ Miklin… - International journal of …, 2017 - Elsevier
… Our aim was to compare radiation exposure among different interventional procedures
In our study we found that the highest radiation exposure was for interventional radiology

Patient radiation dose audits for fluoroscopically guided interventional procedures

S Balter, M Rosenstein, DL Miller, B Schueler… - Medical …, 2011 - Wiley Online Library
… At present, very limited data are available to generate an ADS for any interventional radiology
procedure. A concerted effort to gather the necessary data and create these data sets will …

Radiation exposure to medical staff in interventional and cardiac radiology.

E Vano, L Gonzalez, E Guibelalde… - … journal of radiology, 1998 - academic.oup.com
… staff radiation exposure in catheterization laboraby a parallel increase in the number of …
Patient dosimetry in interventional radiology using slow films. Br J Radiol 1997;70:195–200. …

[PDF][PDF] Practical aspects of radiation protection in interventional radiology

K Faulkner, A Vano, P Ortiz, R Ruiz - … of the International Radiation …, 2000 - irpa.net
… Consideration should be given to possible clinical complications of the procedure and
their impact on the radiation exposure of the patient and possible deterministic effects and to …

… with radiation doses exceeding 5000 mGy reference point air kerma: a dosimetric analysis of 89,549 interventional radiology, neurointerventional radiology, vascular …

JJ Bundy, IW McCracken, DS Shin, EJ Monroe… - CVIR …, 2020 - Springer
… -guided procedures with radiation doses exceeding 5000 mGy … radiation dose” by the
Society of Interventional Radiology. … high radiation doses has the potential to reduce radiation-…

Evaluation of patient radiation dose during cardiac interventional procedures: what is the most effective method?

K Chida, Y Kagaya, H Saito, T Ishibashi… - Acta …, 2009 - Taylor & Francis
… Cardiac interventional radiology has lower risks than surgical procedures. This is despite
the fact that radiation doses from cardiac intervention procedures are the highest of any …

Patient dose in interventional radiology: a European survey

E Vano, H Järvinen, A Kosunen, R Bly… - Radiation protection …, 2008 - academic.oup.com
Interventional radiological (IR) procedures can give rise to significant radiation dose to patients
and can contribute significantly to the total collective dose due to medical exposure, even …

[HTML][HTML] Patient radiation dose in neurointerventional radiologic procedure: a tertiary care experience

K Riabroi, K Khanungwanitkul… - …, 2018 - synapse.koreamed.org
… collect the radiation dose in therapeutic neurointerventional radiology procedures and focus
… Correlation of patient skin doses in cardiac interventional radiology with dose-area product. …