Treatment planning and dosimetric comparison study on two different volumetric modulated arc therapy delivery techniques

SAS Kumar, R Holla, P Sukumar… - Reports of practical …, 2013 - journals.viamedica.pl
… Background: Volumetric modulated arc therapy is a novel technique that has recently been
… Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc

Dosimetric comparison of two arc-based stereotactic body radiotherapy techniques for early-stage lung cancer

H Liu, J Ye, JJ Kim, J Deng, MS Kaur, ZJ Chen - Medical Dosimetry, 2015 - Elsevier
arcs for this study. This decision may put the RapidArc plans in a better position for comparison,
but we believe the results are more useful clinically than a single-arc theoretical study. …

Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT & Arc technique for esophageal carcinoma

S Martin, JZ Chen, AR Dar, S Yartsev - Radiotherapy and Oncology, 2011 - Elsevier
RapidArc plan quality was significantly improved through the inclusion of additional arcs at
the planning stages for patients in this study, as evidenced by lower doses to the lung as well …

Dosimetric verification of RapidArc treatment delivery

S Korreman, J Medin, F Kjaer-Kristoffersen - Acta oncologica, 2009 - Taylor & Francis
… The purpose of the installation was to perform measurements to verify the correctness of
doses delivered with the RapidArc technique. In May 2008, the clinical release of the RapidArc

Comparison of plan quality and delivery time between volumetric arc therapy (RapidArc) and Gamma Knife radiosurgery for multiple cranial metastases

EM Thomas, RA Popple, X Wu, GM Clark… - …, 2014 - journals.lww.com
… Differences between GK 4C and PFX in a dosimetric point of … So, in terms of a dosimetric
comparison, 4-arc VMAT may … The study here describes a dosimetric comparison. We can …

[HTML][HTML] Dosimetric comparison between RapidArc and HyperArc techniques in salvage stereotactic body radiation therapy for recurrent nasopharyngeal carcinoma

HW Ho, SP Lee, HM Lin, HY Chen, CC Huang… - Radiation …, 2020 - Springer
… We have thus employed the concept of BED (or EQD2) to guide our salvage SBRT
planning (Table 2) and provided the dosimetric comparisons between RA & HA techniques …

Dosimetry comparison between volumetric modulated arc therapy with RapidArc and fixed field dynamic IMRT for local-regionally advanced nasopharyngeal …

B Zheng, X Dong, H Wu, Y Duan, S Han… - Chinese Journal of Cancer …, 2011 - Springer
… this study, RapidArc was compared at the reference of the fixed 9-field IMRT in dosimetry for
… local advanced NPC, RapidArc can reach similar target conformity comparing to IMRT for …

Dosimetric comparison of RapidArc with fixed gantry intensity-modulated radiotherapy treatment for multiple liver metastases radiotherapy

Y Yin, C Ma, M Gao, J Chen, Y Ma, T Liu, J Lu, J Yu - Medical Dosimetry, 2011 - Elsevier
… We wanted to compare the dosimetric difference and treatment efficiency of RapidArc and
… IMRT plans were generated using 5 fields and RapidArc using either 1 or 2 arcs. The dose …

A dosimetric comparison of RapidArc and IMRT with hypofractionated simultaneous integrated boost to the prostate for treatment of prostate cancer

K Ishii, R Ogino, W Okada, R Nakahara… - The British Journal of …, 2013 - academic.oup.com
… also made for RapidArc planning for a fair comparison in this study. Finally, we compared
optimal RapidArc, 7-… All the RapidArc plans generated in this study used two arcs because one-…

RapidArc radiotherapy planning for prostate cancer: single-arc and double-arc techniques vs. intensity-modulated radiotherapy

HCK Sze, MCH Lee, WM Hung, TK Yau, AWM Lee - Medical Dosimetry, 2012 - Elsevier
… In this study, we compared the performance of 2 RapidArc … absolute difference in the
dosimetric parameters between the … Some previous studies on dosimetric comparison in prostate-…