Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of …

P Clauser, G Nagl, TH Helbich… - European journal of …, 2016 - Elsevier
… The acquisition and reading time of DBT are well-known issues and have been addressed
… , our results are comparable with respect to reading time to those reported by Bernardi et al. […

Can digital breast tomosynthesis replace full-field digital mammography? A multireader, multicase study of wide-angle tomosynthesis

D Georgian-Smith, NA Obuchowski… - American Journal of …, 2019 - Am Roentgen Ray Soc
… on reading time. … reading algorithms on reading time and efficiency were speculated as
reasons to conduct our study but were not directly tested. Further investigation of reading time

Clinical performance of breast tomosynthesis as a function of radiologist experience level

AP Smith, EA Rafferty, L Niklason - … , IWDM 2008 Tucson, AZ, USA, July 20 …, 2008 - Springer
… This study reports the performance of breast tomosynthesis (3D images) combined … readers
in a blinded reader study. All radiologists’ performance improved using breast tomosynthesis

Digital breast tomosynthesis: concepts and clinical practice

A Chong, SP Weinstein, ES McDonald, EF Conant - Radiology, 2019 - pubs.rsna.org
… longer reading times than DM (15,18), interpretation time is … To address reader efficiency,
new presentation modes, … early reader studies have been shown to decrease reading time by …

Double reading of automated breast ultrasound with digital mammography or digital breast tomosynthesis for breast cancer screening

JM Lee, SC Partridge, GJ Liao, DS Hippe, AE Kim… - Clinical Imaging, 2019 - Elsevier
… digital mammography (FFDM) and digital breast tomosynthesis (DBT), and supplemental
screening methods such as whole breast ultrasound aim to improve early cancer detection. …

Digital breast tomosynthesis practice patterns following 2011 FDA approval: a survey of breast imaging radiologists

Y Gao, JS Babb, HK Toth, L Moy, SL Heller - Academic radiology, 2017 - Elsevier
… Longer reading time of DBT versus 2D is one of the challenges in adopting DBT (29). In our
study, reported reading time … on average shorter reading times as compared to newer users. …

A new approach to digital breast tomosynthesis for breast cancer screening

RM Nishikawa, I Reiser, P Seifi… - Medical Imaging 2007 …, 2007 - spiedigitallibrary.org
breast tomosynthesis (DBT) is being proposed as a replacement for conventional mammography
for breast … imaging microcalcifications and increased reading times by radiologists. We …

Breast tomosynthesis: state-of-the-art and review of the literature

JA Baker, JY Lo - Academic radiology, 2011 - academicradiology.org
Breast tomosynthesis is a new imaging technique designed to eliminate the issue of
overlapping tissue. This new technique has the potential to reduce false positive exams while …

Breast tomosynthesis: what do we know and where do we stand?

C Mandoul, C Verheyden, I Millet, C Orliac… - Diagnostic and …, 2019 - Elsevier
… Additional reading time Reading time is almost doubled with DBT compared to DM, increasing
… views and ultrasound in dense breasts, this additional time does not weigh significantly. …

[PDF][PDF] Fundamentals of breast tomosynthesis

A Smith - White Paper, Hologic Inc., WP-00007, 2008 - Citeseer
… -center, multi-reader trial investigating the performance of tomosynthesis.The purpose of the
… using conventional digital mammography (2D) plus breast tomosynthesis (3D), to the cancer …