[PDF][PDF] The effects of regional pulmonary blood flow on protein flux measurements with PET

A Hamvas, JD Kaplan, J Markham… - Journal of Nuclear …, 1992 - Soc Nuclear Med
RESULTS RA BalloonGroup After inflation of the atrial balloon, cardiac output decreased
40% ±6%. There was no change in the other hemodynamic parameters (Table 1). With the …

[PDF][PDF] Measurement of regional pulmonary blood flow with PET

DP Schuster, JD Kaplan, K Gauvain… - Journal of Nuclear …, 1995 - Soc Nuclear Med
121 ±32 mVminhlOOml lung, andwas 57 ±33 mtfmin/100ml lung in the patients with
cardiomyopathy. The correlation be tweenPBFmeasuredw@ i150 …

Myocardial blood flow measurement by PET: technical aspects and clinical applications

PA Kaufmann, PG Camici - Journal of Nuclear Medicine, 2005 - Soc Nuclear Med
The availability of plastic microspheres labeled with different-emitting isotopes has allowed
the quantification of blood flow in different organs, including the heart (1). In the past 3 …

Comparison of PET with radioactive microspheres to assess pulmonary blood flow

JC Richard, M Janier, F Decailliot… - Journal of Nuclear …, 2002 - Soc Nuclear Med
Microsphere technique is the reference for assessment of pulmonary blood flow (PBF) but is
destructive; PET, however, can determine PBF noninvasively. Comparisons of these 2 …

Simple and accurate assessment of forward cardiac output by use of 1-11C-acetate PET verified in a pig model

J Sörensen, E Ståhle, B Långström… - Journal of Nuclear …, 2003 - Soc Nuclear Med
Dynamic 1-11C-acetate PET (AC-PET) allows quantification of myocardial blood flow and
oxidative metabolism. We wanted to determine the accuracy of AC-PET in measuring …

Variation in maximum counting rates during myocardial blood flow quantification using 82Rb PET

JD van Dijk, PL Jager, JAC van Osch… - Journal of Nuclear …, 2017 - Soc Nuclear Med
Systems for Accurate Quantification of Myocardial Blood Flow”(1). The authors describe a
method to obtain the maximum injected activity for which accurate quantification of …

[引用][C] Practical procedures and pharmacological applications of quantitative PET

SC Huang, ME Phelps - Journal of Nuclear Medicine, 1993 - Soc Nuclear Med
For quantitativePET studies, there are other approaches with different advantagesand
limitationsthat one can considerfor measuringblood TACs without arterial blood sam plings …

Improvement of algorithm for quantification of regional myocardial blood flow using 15O-water with PET

C Katoh, K Morita, T Shiga, N Kubo… - Journal of Nuclear …, 2004 - Soc Nuclear Med
15O-Water and dynamic PET allow noninvasive quantification of myocardial blood flow
(MBF). However, complicated image analyzing procedures are required, which may limit the …

Reproducibility of measurements of regional myocardial blood flow in a model of coronary artery disease: comparison of H215O and 13NH3 PET techniques

P Chareonthaitawee, SD Christenson… - Journal of Nuclear …, 2006 - Soc Nuclear Med
PET absolute myocardial blood flow (MBF) with H215O and 13NH3 are widely used in
clinical and research settings. However, their reproducibility with a 16-myocardial segment …

Measurement of myocardial blood flow with PET using 1-11C-acetate

RR Sciacca, O Akinboboye, RL Chou… - Journal of Nuclear …, 2001 - Soc Nuclear Med
11C-acetate has been used extensively for the noninvasive assessment of myocardial
oxygen consumption and viability with PET. The use of early uptake of acetate by the heart …