Bony increased-offset–reverse shoulder arthroplasty: 5 to 10 years' follow-up

P Boileau, N Morin-Salvo, C Bessière, M Chelli… - Journal of Shoulder and …, 2020 - Elsevier
Background Glenoid lateralization has been shown to be the most imortant factor in
maximizing passive range of motion and shoulder stability while preventing scapular …

Factors influencing appropriate implant selection and position in reverse total shoulder arthroplasty

J Callegari, G Haidamous… - Orthopedic …, 2021 - orthopedic.theclinics.com
More lateralized designs lower the rate of scapular notching and lead to improved external
rotation owing to increased tension on the remaining rotator cuff musculature. Range of …

Lateralization in reverse shoulder arthroplasty

S Bauer, J Corbaz, GS Athwal, G Walch… - Journal of Clinical …, 2021 - mdpi.com
Indications for Reverse Shoulder Arthroplasty (RSA) have been extended over the last 25
years, and RSA has become the most frequently implanted shoulder arthroplasty worldwide …

A comparison of concentric and eccentric glenospheres in reverse shoulder arthroplasty: a randomized controlled trial

PC Poon, J Chou, SW Young, T Astley - JBJS, 2014 - journals.lww.com
Background: Inferior scapular notching following reverse shoulder arthroplasty is due to
mechanical impingement and, in some studies, has been associated with poorer functional …

Effect of Glenosphere Diameter and Lateralization in Primary Reverse Shoulder Arthroplasty: A Randomized Clinical Trial

EM Marigi, RN Esper, DR Larson, ME Morrey… - Seminars in Arthroplasty …, 2024 - Elsevier
Background Within reverse total shoulder arthroplasty (RSA) prior studies have suggested
that smaller glenosphere diameters may result in higher rates of scapular notching and …

The effect of glenoid bone loss on reverse shoulder arthroplasty baseplate fixation

NT Formaini, NG Everding, JC Levy, BG Santoni… - Journal of shoulder and …, 2015 - Elsevier
Background Glenoid bone loss is commonly observed during primary and revision reverse
shoulder arthroplasty. Glenoid baseplates are often implanted with incomplete glenoid bone …

Mini-augmented glenoid baseplate and mini-humeral tray reverse total shoulder arthroplasty implant comparisons: two-year clinical outcomes

R Krupp, C O'Grady, B Werner, JM Wiater… - European Journal of …, 2024 - Springer
Background Augmented glenoid baseplate and offset humeral tray reverse total shoulder
arthroplasty (RTSA) implants may decrease the mechanical impingement that creates …

Lateralising reverse shoulder arthroplasty using bony increased offset (BIO-RSA) or increasing glenoid component diameter: comparison of clinical, radiographic and …

AA Macken, GA Buijze, M Kimmeyer, T Hees… - Journal of Orthopaedics …, 2024 - Springer
Background This study aims to compare the range of motion (ROM) of reverse shoulder
arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) …

Baseplate retroversion does not affect postoperative outcomes after reverse shoulder arthroplasty

R Elmallah, D Swanson, K Le, J Kirsch… - Journal of Shoulder and …, 2022 - Elsevier
Background There is concern that excessive glenoid component retroversion leads to
altered biomechanics and baseplate failure in reverse shoulder arthroplasty (RSA) …

Outcomes and complications of revision reverse shoulder arthroplasty following failed primary reverse shoulder arthroplasty: a systematic review

MA Bethell, ET Hurley, A Meyer, JM Welch… - Seminars in Arthroplasty …, 2023 - Elsevier
ABSTRACT BACKGROUND The purpose of this study is to systematically review the
evidence in the literature to assess the functional outcomes, satisfaction scores, range of …