Effect of assuming constant tissue scattering on measured tissue oxygenation values during tissue ischemia and vascular reperfusion 2

KD Alexander, TJ Barstow - journals.physiology.org
The purpose of this study was to determine the effects of assuming constant tissue 26
scattering properties on tissue oxygenation measurements during a vascular occlusion test …

Effect of assuming constant tissue scattering on measured tissue oxygenation values during tissue ischemia and vascular reperfusion

SM Hammer, DM Hueber… - Journal of Applied …, 2019 - journals.physiology.org
The purpose of this study was to determine the effects of assuming constant tissue scattering
properties on tissue oxygenation measurements during a vascular occlusion test (VOT) …

Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test

K Steenhaut, K Lapage, T Bové, S De Hert… - Journal of clinical …, 2017 - Springer
An increasing number of NIRS devices are used to provide measurements of peripheral
tissue oxygen saturation (S t O 2). The aim of the present study is to test the hypothesis that …

Comparison of two devices using near-infrared spectroscopy for the measurement of tissue oxygenation during a vascular occlusion test in healthy volunteers (INVOS …

JH Lee, YH Park, HS Kim, JT Kim - Journal of clinical monitoring and …, 2015 - Springer
The aim of this study was to compare tissue oxygen saturation as measured by INVOS® and
InSpectra™ during a vascular occlusion test (VOT) in the same subject. Twenty healthy …

Tissue oxygenation index reflects changes in forearm blood flow after brief ischemia

H Kinoshita, T Akahori, E Nakamura… - The Journal of Medical …, 2017 - jstage.jst.go.jp
Whether the near-infrared spectroscopy (NIRS) technology correctly detects the changes in
oxygenation related to ischemia and reperfusion of organs and tissues other than brain …

[HTML][HTML] Evaluation of different near-infrared spectroscopy devices for assessing tissue oxygenation with a vascular occlusion test in healthy volunteers

J Chung, SH Ji, YE Jang, EH Kim, JH Lee… - Journal of Vascular …, 2020 - karger.com
Near-infrared spectroscopy devices can measure peripheral tissue oxygen saturation (StO
2). This study aims to compare StO 2 using INVOS® and different O3™ settings (O3 25: 75 …

[HTML][HTML] Microvascular effects of oxygen and carbon dioxide measured by vascular occlusion test in healthy volunteers

CK Niezen, JJ Vos, AF Bos, TWL Scheeren - Microvascular research, 2023 - Elsevier
Background Changes in near-infrared spectroscopy-derived regional tissue oxygen
saturation (StO 2) during a vascular occlusion test (VOT; ischemic provocation of …

Spatial sensitivity of nirs tissue oxygenation measurement using a simplified instrument

R Liu, X Liu, F Scopesi, G Serra, JW Sun… - 7th Asian-Pacific …, 2008 - Springer
N ear infra red spectroscopy (NIRS) is of interest for chemical and structural analysis in cells,
tissues and organs. We describe simplified instrumentation aimed at clinical applications …

Measuring Tissue Oxygen Saturation Using NIR Spectroscopy

ASK Aslinur-Sircan-Kucuksayan, M Uyuklu… - 2014 - openaccess.bezmialem.edu.tr
Abstract Tissue oxygen saturation (StO (2)) is known quite useful parameter for medical
applications. A spectroscopic method has been developed to diagnose pathologic tissues …

[HTML][HTML] 500 ml of blood loss does not decrease non-invasive tissue oxygen saturation (StO2) as measured by near infrared spectroscopy - A hypothesis generating …

V Jeger, SM Jakob, S Fontana, M Wolf… - Journal of trauma …, 2010 - Springer
Background The goal when resuscitating trauma patients is to achieve adequate tissue
perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO 2), as …