A thermometry software tool for monitoring laser-induced interstitial thermotherapy
B Bazrafshan, A Koujan, F Hübner… - Biomedical …, 2019 - degruyter.com
The purpose of this study was to develop a thermometry software tool for temperature
monitoring during laser-induced interstitial thermotherapy (LITT). C++ programming …
monitoring during laser-induced interstitial thermotherapy (LITT). C++ programming …
MRI thermodosimetry in laser‐induced interstitial thermotherapy
M Prudhomme, M Mattéi‐Gazagnes… - Lasers in Surgery …, 2003 - Wiley Online Library
Abstract Background and Objectives The aim of this study was to establish a correlation
between a thermal measurement and a magnetic resonance imaging (MRI) signal during …
between a thermal measurement and a magnetic resonance imaging (MRI) signal during …
Validating a simulation model for laser-induced thermotherapy using MR thermometry
F Hübner, S Blauth, C Leithäuser… - International Journal …, 2022 - Taylor & Francis
Objectives We want to investigate whether temperature measurements obtained from MR
thermometry are accurate and reliable enough to aid the development and validation of …
thermometry are accurate and reliable enough to aid the development and validation of …
Monitoring of interstitial laser thermotherapy with heat-sensitive colour subtraction magnetic resonance imaging: calibration with absolute tissue temperature and …
SWT Gould, NV Vaughan, W Gedroyc, G Lamb… - Lasers in Medical …, 1999 - Springer
Magnetic resonance imaging (MR) is the most sensitive modality for monitoring interstitial
thermotherapy (ILT). A real-time pulse sequence that assigns a colour spectrum to grey …
thermotherapy (ILT). A real-time pulse sequence that assigns a colour spectrum to grey …
Improved quantitative MR thermometry using a 1.5-T scanner to monitor cooled applicator systems during laser-induced interstitial thermotherapy (LITT)
H Busse, M Rassek, A Grust, T Kahn… - … Treatment of Tissue …, 1999 - spiedigitallibrary.org
Cooled LITT applicator systems are known to induce complex temperature patterns. Typical
for such devices, the temperature maxima are often shifted away from the applicator into the …
for such devices, the temperature maxima are often shifted away from the applicator into the …
Determination of the lesion size in laser-induced interstitial thermal therapy (LITT) using a low-field MRI
R Viard, A Emptaz, B Piron, P Rochon… - 2007 29th Annual …, 2007 - ieeexplore.ieee.org
This study aimed to compare MR thermal mapping during laser-induced interstitial thermal
therapy (LITT) to thermal lesions observed macroscopically, in order to estimate the 3D size …
therapy (LITT) to thermal lesions observed macroscopically, in order to estimate the 3D size …
Development of an application set for intraoperative and percutaneous laser-induced interstitial thermotherapy (LITT)
A Roggan, D Albrecht, HP Berlien… - … of Lasers II, 1994 - spiedigitallibrary.org
A variable application-set was developed to enable a safe and effective LITT treatment. The
set consists of various laser applicators, a protecting catheter and an introducing equipment …
set consists of various laser applicators, a protecting catheter and an introducing equipment …
In situ temperature measurements with thermocouple probes during laser interstitial thermotherapy (LITT): quantification and correction of a measurement artifact
F Manns, PJ Milne, X Gonzalez‐Cirre… - Lasers in Surgery …, 1998 - Wiley Online Library
Abstract Background and Objective: The purpose of this work was to quantify the magnitude
of an artifact induced by stainless steel thermocouple probes in temperature measurements …
of an artifact induced by stainless steel thermocouple probes in temperature measurements …
Monitoring of temperature increase and tissue vaporization during laser interstitial thermotherapy of ex vivo swine liver by computed tomography
Monitoring of temperature increase and tissue vaporization during laser interstitial
thermotherapy of ex vivo swine liver by com Page 1 Abstract― Laser interstitial thermotherapy …
thermotherapy of ex vivo swine liver by com Page 1 Abstract― Laser interstitial thermotherapy …
The influence of Nd: YAG laser irradiation on Fluoroptic® temperature measurement: an experimental evaluation
F Hübner, B Bazrafshan, J Roland, A Kickhefel… - Lasers in medical …, 2013 - Springer
The aim of this study was to experimentally evaluate temperature monitoring with a
Fluoroptic® temperature probe in the presence of laser irradiation from a Nd: YAG laser …
Fluoroptic® temperature probe in the presence of laser irradiation from a Nd: YAG laser …