A tracking Compton-scattering imaging system for hadron therapy monitoring

M Frandes, A Zoglauer, V Maxim… - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
Hadron therapy for, eg, cancer treatment requires an accurate dose deposition (total amount
and location). As a consequence, monitoring is crucial for the success of the treatment …

Compton camera study for high efficiency SPECT and benchmark with Anger system

M Fontana, D Dauvergne, JM Létang… - Physics in Medicine & …, 2017 - iopscience.iop.org
Single photon emission computed tomography (SPECT) is at present one of the major
techniques for non-invasive diagnostics in nuclear medicine. The clinical routine is mostly …

Gamma-ray imaging with position-sensitive HPGe detectors

K Vetter, M Burks, L Mihailescu - … and Methods in Physics Research Section …, 2004 - Elsevier
Due to advances in manufacturing large and highly segmented HPGe detectors along with
the availability of fast and high-precision digital electronics, it is now possible to build …

Design Guidelines for a Double Scattering Compton Camera for Prompt- Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study

MH Richard, M Chevallier, D Dauvergne… - … on Nuclear Science, 2010 - ieeexplore.ieee.org
In hadrontherapy in order to fully take advantage of the assets of the ion irradiation, the
position of the Bragg peak has to be monitored accurately. Here, we investigate a monitoring …

Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imaging

L Han, WL Rogers, SS Huh… - Physics in Medicine & …, 2008 - iopscience.iop.org
In radionuclide treatment, tumor cells are primarily destroyed by charged particles emitted by
the compound while associated higher energy photons are used to image the tumor in order …

Optimization and verification of image reconstruction for a Compton camera towards application as an on-line monitor for particle therapy

T Taya, J Kataoka, A Kishimoto, L Tagawa… - Journal of …, 2017 - iopscience.iop.org
Particle therapy is an advanced cancer therapy that uses a feature known as the Bragg
peak, in which particle beams suddenly lose their energy near the end of their range. The …

Compton gamma-ray imaging detector with electron tracking

R Orito, H Kubo, K Miuchi, T Nagayoshi… - Nuclear Instruments and …, 2004 - Elsevier
We propose a new gamma-ray imaging detector based on a gaseous time projection
chamber (TPC). The most important feature of this detector is the ability of measuring the …

High-sensitivity Compton imaging with position-sensitive Si and Ge detectors

K Vetter, M Burks, C Cork, M Cunningham… - Nuclear Instruments and …, 2007 - Elsevier
We report on the development of high-sensitivity and compact Compton imaging systems
built of large and position-sensitive Si (Li) and HPGe detectors. The primary goal of this effort …

PSF reconstruction for Compton-based prompt gamma imaging

ML Jan, MW Lee, HM Huang - Physics in Medicine & Biology, 2018 - iopscience.iop.org
Compton-based prompt gamma (PG) imaging has been proposed for in vivo range
verification in proton therapy. However, several factors degrade the image quality of PG …

Optimizing Compton camera geometries

S Chelikani, J Gore, G Zubal - Physics in Medicine & Biology, 2004 - iopscience.iop.org
Compton cameras promise to improve the characteristics of nuclear medicine imaging,
wherein mechanical collimation is replaced with electronic collimation. This leads to huge …