Limitations and late complications of third-generation automatic cardioverter-defibrillators
SO Nunain, M Roelke, T Trouton, S Osswald, YH Kim… - Circulation, 1995 - Am Heart Assoc
Background This study examines the limitations and complex management problems
associated with the use of tiered-therapy, implantable cardioverter-defibrillators (ICDs) …
associated with the use of tiered-therapy, implantable cardioverter-defibrillators (ICDs) …
Complications of third‐generation implantable cardioverter defibrillator therapy
W Grimm, V Menz, J Hoffmann… - Pacing and clinical …, 1999 - Wiley Online Library
To determine the incidence of complications of third‐generation implantable cardioverter
defibrillator (ICD) therapy, 144 patients were prospectively studied who underwent first …
defibrillator (ICD) therapy, 144 patients were prospectively studied who underwent first …
Defibrillation energy requirements with single endocardial (Endotak™) lead
J Winter, EG VESTER, S Kuhls… - Pacing and Clinical …, 1993 - Wiley Online Library
The need for thoracotomy in usually high risk patients has limited the use of the implantable
cardioverter defibrillator. Initial clinical results with endocardial and subcutanous patch …
cardioverter defibrillator. Initial clinical results with endocardial and subcutanous patch …
The “Modern” Implantable Cardioverter-Defribrillator: Comparing It to Those of the Late 1980s
HJ Trappe - The American journal of cardiology, 1996 - Elsevier
To determine whether implantable cardioverter-defibrillator (ICD) therapy is influenced by
new technological advances, we studied the follow-up of 480 patients who underwent ICD …
new technological advances, we studied the follow-up of 480 patients who underwent ICD …
Complications of implantable cardioverter defibrillator therapy: Follow‐up of 241 patients
W Grimm, BF Flores… - Pacing and Clinical …, 1993 - Wiley Online Library
In order to determine the incidence of complications of impJantable cardioverter defibrillator
(ICD) therapy, 241 patients with a total of 353 ICD implantations were followed for 24±20 …
(ICD) therapy, 241 patients with a total of 353 ICD implantations were followed for 24±20 …
Results of the international study of the implantable pacemaker cardioverter-defibrillator: a comparison of epicardial and endocardial lead systems
DP Zipes, D Roberts - Circulation, 1995 - Am Heart Assoc
Background The purpose of the present report was to document clinical experience derived
from the implantation of 2834 epicardial and endocardial cardioverter-defibrillators (ICDs) in …
from the implantation of 2834 epicardial and endocardial cardioverter-defibrillators (ICDs) in …
Management of complications associated with a first-generation endocardial defibrillation lead system for implantable cardioverter-defibrillators
NG Tullo, S Saksena, RB Krol, AM Mauro… - The American journal of …, 1990 - Elsevier
An automatic cardioverter-defibrillator could be implanted using an endocardial defibrillation
lead system (consisting of a tripolar defibrillation electrode catheter in conjunction with an …
lead system (consisting of a tripolar defibrillation electrode catheter in conjunction with an …
Implantable defibrillation: eight years clinical experience
AC Thomas, SA Moser, ML Smutka… - Pacing and Clinical …, 1988 - Wiley Online Library
Implantation of the first automatic defibrillator occurred in February 1980. Incorporation of
cardioversion capability in 1982 resulted in the AICD™ automatic implantable cardioverter …
cardioversion capability in 1982 resulted in the AICD™ automatic implantable cardioverter …
Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients
P Alter, S Waldhans, E Plachta… - Pacing and Clinical …, 2005 - Wiley Online Library
Background: Although more than 150,000 implantable cardioverter defibrillators (ICDs) are
implanted yearly worldwide, only few studies systematically examined complications of ICD …
implanted yearly worldwide, only few studies systematically examined complications of ICD …
Sensing/pacing lead complications with a newer generation implantable cardioverter-defibrillator: worldwide experience from the Guardian ATP 4210 clinical trial
BS Stambler, MA Wood, RJ Damiano… - Journal of the American …, 1994 - Elsevier
Objectives. This report describes the sensing/pacing lead complications that developed
during a worldwide clinical trial of a new impiantable cardioverter-defibrillator. Background …
during a worldwide clinical trial of a new impiantable cardioverter-defibrillator. Background …
相关搜索
- cardioverter defibrillators late complications
- newer generation cardioverter defibrillator
- worldwide experience cardioverter defibrillator
- lead complications newer generation
- cardioverter defribrillator late 1980s
- comparison of epicardial cardioverter defibrillator
- permanent pacemaker cardioverter defibrillator
- cardioverter defibrillators management of complications
- lead complications cardioverter defibrillator