Optimization and validation of a fully‐integrated pulse sequence for modified look‐locker inversion‐recovery (MOLLI) T1 mapping of the heart

DR Messroghli, A Greiser, M Fröhlich… - Journal of Magnetic …, 2007 - Wiley Online Library
Purpose To optimize and validate a fully‐integrated version of modified Look‐Locker
inversion‐recovery (MOLLI) for clinical single‐breathhold cardiac T1 mapping. Materials and …

Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart

DR Messroghli, A Radjenovic… - … in Medicine: An …, 2004 - Wiley Online Library
A novel pulse sequence scheme is presented that allows the measurement and mapping of
myocardial T1 in vivo on a 1.5 Tesla MR system within a single breath‐hold. Two major …

[HTML][HTML] Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold

SK Piechnik, VM Ferreira, E Dall'Armellina… - Journal of …, 2010 - Elsevier
Background T1 mapping allows direct in-vivo quantitation of microscopic changes in the
myocardium, providing new diagnostic insights into cardiac disease. Existing methods …

Myocardial T1 mapping with MRI: comparison of Look‐Locker and MOLLI sequences

MS Nacif, EB Turkbey, N Gai… - Journal of Magnetic …, 2011 - Wiley Online Library
Purpose: To evaluate the relationship between “Look‐Locker”(LL) and modified Look‐
Locker Inversion recovery (MOLLI) approaches for T1 mapping of the myocardium. Materials …

Systolic ShMOLLI myocardial T1-mapping for improved robustness to partial-volume effects and applications in tachyarrhythmias

VM Ferreira, RS Wijesurendra, A Liu, A Greiser… - Journal of …, 2015 - Springer
Background T1-mapping using the Shortened Modified Look-Locker Inversion Recovery
(ShMOLLI) technique enables non-invasive assessment of important myocardial tissue …

Free‐breathing multislice native myocardial T1 mapping using the slice‐interleaved T1 (STONE) sequence

S Weingärtner, S Roujol, M Akçakaya… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose To develop a novel pulse sequence for free‐breathing, multislice, native
myocardial T1 mapping. Methods The slice‐interleaved T1 (STONE) sequence consists of …

Free‐running 3D whole heart myocardial T1 mapping with isotropic spatial resolution

H Qi, O Jaubert, A Bustin, G Cruz… - Magnetic …, 2019 - Wiley Online Library
Purpose To develop a free‐running (free‐breathing, retrospective cardiac gating) 3D
myocardial T1 mapping with isotropic spatial resolution. Methods The free‐running …

Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2‐preparation

M Akçakaya, S Weingärtner, TA Basha… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose To develop a heart‐rate independent breath‐held joint T1–T2 mapping sequence
for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. Methods …

T1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequences

MD Robson, SK Piechnik… - Magnetic resonance …, 2013 - Wiley Online Library
Purpose Quantitative mapping of the native T1 of the heart using the modified look‐locker
inversion recovery (MOLLI) technique provides high quality diagnostic information without …

[HTML][HTML] T1-mapping in the heart: accuracy and precision

P Kellman, MS Hansen - Journal of cardiovascular magnetic resonance, 2014 - Elsevier
The longitudinal relaxation time constant (T1) of the myocardium is altered in various
disease states due to increased water content or other changes to the local molecular …