A simplified analytical dose calculation algorithm accounting for tissue heterogeneity for low-energy brachytherapy sources

S Mashouf, E Lechtman, L Beaulieu… - Physics in Medicine …, 2013 - iopscience.iop.org
Abstract The American Association of Physicists in Medicine Task Group No. 43 (AAPM TG-
43) formalism is the standard for seeds brachytherapy dose calculation. But for breast seed …

An analytical dosimetry model as a step towards accounting for inhomogeneities and bounded geometries in 192Ir brachytherapy treatment planning

G Anagnostopoulos, D Baltas… - Physics in Medicine …, 2003 - iopscience.iop.org
A simple analytical dose rate calculation model based on primary and scatter separation that
treats 192 Ir as a monoenergetic source by use of appropriate attenuation and mass energy …

Monte Carlo dose calculations for breast and lung permanent implant brachytherapy

J Sutherland - 2013 - repository.library.carleton.ca
Current clinical practice for dose calculations for brachytherapy utilizes the TG-43 formalism
where absorbed dose is calculated in a homogeneous water environment. The formalism …

A generic high‐dose rate 192Ir brachytherapy source for evaluation of model‐based dose calculations beyond the TG‐43 formalism

F Ballester, Å Carlsson Tedgren, D Granero… - Medical …, 2015 - Wiley Online Library
Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from
the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG‐43) …

Anisotropy functions for low energy interstitial brachytherapy sources: An EGS4 Monte Carlo study

R Capote, E Mainegra, E López - Physics in Medicine & Biology, 2001 - iopscience.iop.org
Anisotropy functions for low energy interstitial brachytherapy sources are examined.
Absolute dose rates around 103 Pd seed model 200 and 125 I seed models 6702 and 6711 …

Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: current status and recommendations for …

L Beaulieu, Å Carlsson Tedgren, JF Carrier… - Medical …, 2012 - Wiley Online Library
The charge of Task Group 186 (TG‐186) is to provide guidance for early adopters of model‐
based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to …

A brief look at model-based dose calculation principles, practicalities, and promise

RS Sloboda, H Morrison, B Cawston-Grant… - Journal of …, 2017 - termedia.pl
Purpose Since its introduction more than twenty years ago, the American Association of
Physicists in Medicine Task Group 43 (AAPM TG-43) dose calculation formalism for photon …

[PDF][PDF] Monte Carlo dosimetry of the most commonly used 192Ir high dose rate brachytherapy sources

JFA López, JT Donaire, RG Alcalde - Rev Fis Med, 2011 - researchgate.net
192Ir high dose rate sources are widely used in brachytherapy applications by inserting
needles and catheters or implants that allow the source to reach tumor lesions in different …

An analytical model to determine interseed attenuation effect in low‐dose‐rate brachytherapy

H Safigholi, D Sardari, SK Jashni… - Journal of Applied …, 2013 - Wiley Online Library
Brachytherapy treatment planning systems (BTPS) are employing the American Association
of Physicists in Medicine (AAPM) Task Group 43 (TG‐43)‐recommended dosimetric …

Validation of GPUMCD for low‐energy brachytherapy seed dosimetry

S Hissoiny, B Ozell, P Després, JF Carrier - Medical Physics, 2011 - Wiley Online Library
Purpose: To validate Gpumcd, a new package for fast Monte Carlo dose calculations based
on the GPU (graphics processing unit), as a tool for low‐energy single seed brachytherapy …